Download E5CC-800/E5CC-U-800 Data Sheet
Transcript
E5CC/E5CC-U/E5EC/E5AC/E5DC-800 Press the O Key for at least 1 s. Advanced Function Setting Level alt2 Alarm 2 Type 2 M alh2 Alarm 2 init Parameter Initialization M alt3 Alarm 3 Type M mspu Number of Multi-SP M a1lt Alarm 1 Latch M hsl HS Alarm Latch M pvrp PV Rate of Change M alh3 Alarm 3 M spru SP Ramp Time Unit M a2lt Alarm 2 Latch M hsh HS Alarm Hysteresis M hctm Heating/Cooling M alt4 Alarm 4 Type M Sequence rest Standby Reset M a3lt Alarm 3 Latch M alh4 Alarm 4 M sb1n Auxiliary Output 1 M a4lt Alarm 4 Latch M o1st Control Output 1 Signal M sb2n Auxiliary Output 2 M to Protect Level prlt Move Time Event Input M sb3n Auxiliary Output 3 0.2 Hysteresis 2 0.2 Hysteresis 2 0.2 Hysteresis M msp0 Assignment 1 M Input ev-2 Event Assignment 2 stop M Input ev-3 Event Assignment 3 none M ev-4 off Points m a n-o Open in Alarm n-o Open in Alarm 4-20 ev-1 off Event Input Assignment 4 none M clfl Close/Floating flot M calb Motor Calibration off M mot Travel Time 30 M Move to Advanced Function Setting Level: Displayed when initial 0 setting/communications protect is set to 0. amov M Move by setting password (−169). n-o Open in Alarm M sb4n Auxiliary Output 4 Open in Alarm n-o (E5EC/E5AC-800 only) Display ret Automatic Return Time off off off off off 3 Cold Junction Compensation on Method M a1on Alarm 1 ON Delay 0 M hbu HB ON/OFF a2on M hbl Heater Burnout Latch on off 0.1 M lba LBA Detection Time 0 M lbal LBA Level 8.0 M lbab LBA Band 3.0 M M cjc hsu HS Alarm Use M Output 1 out1 Control Assignment o M Output 2 out2 Control Assignment none M Direct Setting of Position Proportional MV pmvd off 20 Calculation Period off Tuning Method M ompw Minimum Output 1.0 ON/OFF Band M pf PF Setting shft M No. 1 Display spd1 PV/SP Selection 1 M No. 2 Display spd2 PV/SP Selection 0 M odsl MV Display Selection o Output 1 sub1 Auxiliary Assignment M Status Display pvst PV Function M a3on Alarm 3 ON Delay M Auxiliary Output 2 sub2 Assignment M Status Display svst SV Function M Burnout hbh Heater Hysteresis M a4on Alarm 4 ON Delay M Output 3 sub3 Auxiliary Assignment M Refresh d.ref Display Period M st-b ST Stable Range M a1of Alarm 1 OFF Delay M alma Integrated Alarm M Cooling Output lcmt LCT Minimum ON Time M alfa M a2of Alarm 2 OFF Delay on Alarm 2 ON Delay 0 off 0.1 15.0 α 0.65 0 0 0 M a3of Alarm 3 OFF Delay M inf Input Digital Filter M a4of Alarm 4 OFF Delay M mav Moving Average Count M Select amad Auto/Manual Addition 0.0 8 M MV Display o-dp M off M alm2 alm3 49 Assignment M off off 0.25 0.2 (E5DC-800 only) M 0 M tidu Integral/Derivative 1 Time Unit alm1 0 0 off M mant Manual Output Method hold M mani Manual MV Initial Value M 0.0 M 21