Download E5CC-800/E5CC-U-800 Data Sheet

Transcript
E5CC/E5CC-U/E5EC/E5AC/E5DC-800
Press the O Key
for at least 1 s.
Advanced Function Setting Level
alt2
Alarm 2 Type
2
M
alh2 Alarm 2
init Parameter Initialization
M
alt3 Alarm 3 Type
M
mspu Number of Multi-SP
M
a1lt Alarm 1 Latch
M
hsl HS Alarm Latch
M
pvrp PV Rate of Change
M
alh3 Alarm 3
M
spru SP Ramp Time Unit
M
a2lt Alarm 2 Latch
M
hsh HS Alarm Hysteresis
M
hctm Heating/Cooling
M
alt4 Alarm 4 Type
M
Sequence
rest Standby
Reset
M
a3lt Alarm 3 Latch
M
alh4 Alarm 4
M
sb1n Auxiliary Output 1
M
a4lt Alarm 4 Latch
M
o1st
Control Output 1 Signal
M
sb2n Auxiliary Output 2
M
to Protect Level
prlt Move
Time
Event Input
M
sb3n Auxiliary Output 3
0.2 Hysteresis
2
0.2 Hysteresis
2
0.2 Hysteresis
M
msp0 Assignment 1
M
Input
ev-2 Event
Assignment 2
stop
M
Input
ev-3 Event
Assignment 3
none
M
ev-4
off Points
m
a
n-o Open in Alarm
n-o Open in Alarm
4-20
ev-1
off
Event Input
Assignment 4
none
M
clfl Close/Floating
flot
M
calb Motor Calibration
off
M
mot Travel Time
30
M
Move to Advanced Function
Setting Level:
Displayed when initial
0
setting/communications
protect is set to 0.
amov
M
Move by setting password (−169).
n-o Open in Alarm
M
sb4n Auxiliary Output 4
Open in Alarm
n-o
(E5EC/E5AC-800 only)
Display
ret Automatic
Return Time
off
off
off
off
off
3
Cold Junction
Compensation
on Method
M
a1on Alarm 1 ON Delay
0
M
hbu HB ON/OFF
a2on
M
hbl Heater Burnout Latch
on
off
0.1
M
lba LBA Detection Time
0
M
lbal LBA Level
8.0
M
lbab LBA Band
3.0
M
M
cjc
hsu HS Alarm Use
M
Output 1
out1 Control
Assignment
o
M
Output 2
out2 Control
Assignment
none
M
Direct Setting of
Position Proportional
MV
pmvd
off
20 Calculation Period
off Tuning Method
M
ompw Minimum Output
1.0 ON/OFF Band
M
pf PF Setting
shft
M
No. 1 Display
spd1 PV/SP
Selection
1
M
No. 2 Display
spd2 PV/SP
Selection
0
M
odsl
MV Display Selection
o
Output 1
sub1 Auxiliary
Assignment
M
Status Display
pvst PV
Function
M
a3on Alarm 3 ON Delay
M
Auxiliary Output 2
sub2 Assignment
M
Status Display
svst SV
Function
M
Burnout
hbh Heater
Hysteresis
M
a4on Alarm 4 ON Delay
M
Output 3
sub3 Auxiliary
Assignment
M
Refresh
d.ref Display
Period
M
st-b ST Stable Range
M
a1of Alarm 1 OFF Delay
M
alma Integrated Alarm
M
Cooling Output
lcmt LCT
Minimum ON Time
M
alfa
M
a2of Alarm 2 OFF Delay
on
Alarm 2 ON Delay
0
off
0.1
15.0
α
0.65
0
0
0
M
a3of Alarm 3 OFF Delay
M
inf Input Digital Filter
M
a4of Alarm 4 OFF Delay
M
mav Moving Average Count
M
Select
amad Auto/Manual
Addition
0.0
8
M
MV Display
o-dp
M
off
M
alm2
alm3
49 Assignment
M
off
off
0.25
0.2 (E5DC-800 only)
M
0
M
tidu Integral/Derivative
1 Time Unit
alm1
0
0
off
M
mant Manual Output Method
hold
M
mani Manual MV Initial Value
M
0.0
M
21