Download User Manual High Performance AC Drive
Transcript
717 Data In C2 Int 718 719 720 721 722 723 Link C Word 2 (Integer) - Parameter number whose value will be written from a communications device data table. Parameters that can only be changed while the drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will "Disable" the link. Refer to the manual that came with your communications option for datalink information. Data In C2 Real Default: Link C Word 2 (Real or Floating Point) - Parameters that can only be changed while the Min/Max: drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will "Disable" the link. Refer to the manual that came with your communications option for datalink information. Default: Data In D1 Int Link D Word 1 (Integer) - Parameter number whose value will be written from a Min/Max: communications device data table. Parameters that can only be changed while the drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will "Disable" the link. Refer to the manual that came with your communications option for datalink information. Default: Data In D1 Real Link D Word 1 (Real or Floating Point) - Parameters that can only be changed while the Min/Max: drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will "Disable" the link. Refer to the manual that came with your communications option for datalink information. Default: Data In D2 Int Link D Word 2 (Integer) - Parameter number whose value will be written from a Min/Max: communications device data table. Parameters that can only be changed while the drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will "Disable" the link. Refer to the manual that came with your communications option for datalink information. Default: Data In D2 Real Link D Word 2 (Real or Floating Point) - Parameters that can only be changed while the Min/Max: drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will "Disable" the link. Refer to the manual that came with your communications option for datalink information. Data Out A1 Int 725 Data Out A1 Real 729 730 731 732 Reserved D2 Out Real D1 Out Real C2 Out Real C1 Out Real B2 Out Real B1 Out Real A2 Out Real A1 Out Real Reserved Reserved Reserved Reserved Reserved Reserved Reserved 0 0 0 0 0 0 0 15 14 13 12 11 10 9 724 728 32-bit Integer 0.0000 -/+2200000000.0000 Real 0 -/+2147483648 32-bit Integer 0.0000 -/+2200000000.0000 Real 0 -/+2147483648 32-bit Integer 0.0000 -/+2200000000.0000 Real Set bits to configure each Datalink output word for real (floating point) data transfer. Reset bits to configure each Datalink output word for integer data transfer. Default Bit 727 0 -/+2147483648 DLink OutDataTyp Options 726 Values Default: Min/Max: Data Type Name Description 3-69 Read-Write No. Linkable Programming and Parameters 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 Link A Word 1 (Integer) - Parameter number whose value will be written to a communications device data table. 0 = False 1 = True Default: Min/Max: Default: Link A Word 1 (Real or Floating Point) - Parameter number whose value will be written to Min/Max: a communications device data table. Default: Data Out A2 Int Link A Word 2 (Integer) - Parameter number whose value will be written to a Min/Max: communications device data table. Default: Data Out A2 Real Link A Word 2 (Real or Floating Point) - Parameter number whose value will be written to Min/Max: a communications device data table. Default: Data Out B1 Int Link B Word 1 (Integer) - Parameter number whose value will be written to a Min/Max: communications device data table. Default: Data Out B1 Real Link B Word 1 (Real or Floating Point) - Parameter number whose value will be written to Min/Max: a communications device data table. Default: Data Out B2 Int Link B Word 2 (Integer) - Parameter number whose value will be written to a Min/Max: communications device data table. Default: Data Out B2 Real Link B Word 2 (Real or Floating Point) - Parameter number whose value will be written to Min/Max: a communications device data table. Default: Data Out C1 Int Link C Word 1 (Integer) - Parameter number whose value will be written to a Min/Max: communications device data table. 0 -/+2147483648 ✓ ✓ 32-bit Integer 0.0000 -/+2200000000.0000 ✓ ✓ Real 0 -/+2147483648 ✓ ✓ 32-bit Integer 0.0000 -/+2200000000.0000 ✓ ✓ Real 0 -/+2147483648 ✓ ✓ 32-bit Integer 0.0000 -/+2200000000.0000 ✓ ✓ Real 0 -/+2147483648 ✓ ✓ 32-bit Integer 0.0000 -/+2200000000.0000 ✓ ✓ Real 0 -/+2147483648 ✓ ✓ 32-bit Integer