Download User Manual High Performance AC Drive

Transcript
717
Data In C2 Int
718
719
720
721
722
723
Link C Word 2 (Integer) - Parameter number whose value will be written from a
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Data In C2 Real
Default:
Link C Word 2 (Real or Floating Point) - Parameters that can only be changed while the Min/Max:
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Data In D1 Int
Link D Word 1 (Integer) - Parameter number whose value will be written from a
Min/Max:
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Data In D1 Real
Link D Word 1 (Real or Floating Point) - Parameters that can only be changed while the Min/Max:
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Data In D2 Int
Link D Word 2 (Integer) - Parameter number whose value will be written from a
Min/Max:
communications device data table. Parameters that can only be changed while the drive
is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Default:
Data In D2 Real
Link D Word 2 (Real or Floating Point) - Parameters that can only be changed while the Min/Max:
drive is stopped cannot be used as Datalink inputs. Entering a parameter of this type will
"Disable" the link. Refer to the manual that came with your communications option for
datalink information.
Data Out A1 Int
725
Data Out A1 Real
729
730
731
732
Reserved
D2 Out Real
D1 Out Real
C2 Out Real
C1 Out Real
B2 Out Real
B1 Out Real
A2 Out Real
A1 Out Real
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
0 0 0 0 0 0 0
15 14 13 12 11 10 9
724
728
32-bit
Integer
0.0000
-/+2200000000.0000
Real
0
-/+2147483648
32-bit
Integer
0.0000
-/+2200000000.0000
Real
0
-/+2147483648
32-bit
Integer
0.0000
-/+2200000000.0000
Real
Set bits to configure each Datalink output word for real (floating point) data transfer. Reset bits to configure each Datalink output word for integer data transfer.
Default
Bit
727
0
-/+2147483648
DLink OutDataTyp
Options
726
Values
Default:
Min/Max:
Data Type
Name
Description
3-69
Read-Write
No.
Linkable
Programming and Parameters
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
Link A Word 1 (Integer) - Parameter number whose value will be written to a
communications device data table.
0 = False
1 = True
Default:
Min/Max:
Default:
Link A Word 1 (Real or Floating Point) - Parameter number whose value will be written to Min/Max:
a communications device data table.
Default:
Data Out A2 Int
Link A Word 2 (Integer) - Parameter number whose value will be written to a
Min/Max:
communications device data table.
Default:
Data Out A2 Real
Link A Word 2 (Real or Floating Point) - Parameter number whose value will be written to Min/Max:
a communications device data table.
Default:
Data Out B1 Int
Link B Word 1 (Integer) - Parameter number whose value will be written to a
Min/Max:
communications device data table.
Default:
Data Out B1 Real
Link B Word 1 (Real or Floating Point) - Parameter number whose value will be written to Min/Max:
a communications device data table.
Default:
Data Out B2 Int
Link B Word 2 (Integer) - Parameter number whose value will be written to a
Min/Max:
communications device data table.
Default:
Data Out B2 Real
Link B Word 2 (Real or Floating Point) - Parameter number whose value will be written to Min/Max:
a communications device data table.
Default:
Data Out C1 Int
Link C Word 1 (Integer) - Parameter number whose value will be written to a
Min/Max:
communications device data table.
0
-/+2147483648
✓ ✓ 32-bit
Integer
0.0000
-/+2200000000.0000
✓ ✓ Real
0
-/+2147483648
✓ ✓ 32-bit
Integer
0.0000
-/+2200000000.0000
✓ ✓ Real
0
-/+2147483648
✓ ✓ 32-bit
Integer
0.0000
-/+2200000000.0000
✓ ✓ Real
0
-/+2147483648
✓ ✓ 32-bit
Integer
0.0000
-/+2200000000.0000
✓ ✓ Real
0
-/+2147483648
✓ ✓ 32-bit
Integer