Download PowerFlex 700S High Performance AC Drive

Transcript
282
Opt 1 Regis Stat
287
288
289
290
297
298
299
300
301
302
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Found
Armed
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
Reserved
Default
Bit
Reserved
Options
Reserved
Displays the registration control status of port 1 on the feedback option card.
• Bit 0 [Armed] indicates the when the registration latch has been armed.
Bit 1 [Found] indicates that the registration event has triggered the latch.
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
0 = True
1 = False
Linear1 Status
Default:
Linear1 TP Sel
Enter or write a value to select Linear Feedback data data displayed in Parameter 288 Options:
[Linear1 TP Data].
• Value 0 - Zero displays a value of zero.
• Value 1 - HO Edge Time displays the change displays the latency or edge time (the
time since the last update of Parameter 276 [FB Opt1 Posit]).
• Value 2 - HO dEdge displays the change in Parameter 276 [FB Opt1 Posit] since the
last feedback sample.
• Value 3 - HO DTime displays the change in time since the last feedback sample Note
the sample rate is 10,000 counts per second (10 Mhz).
• Value 4 - HO EPR displays the change in edges per motor revolution. This number is
the same value in Parameter 290 [Linear1 CPR].
• Value 5 - Edge Mode displays ?
• Value 6 - HO dTheta displays the numerator term for speed calculation. This number
divided by change in time (TP3) is the calculated per unit speed for the linear feedback
sensor.
Default:
Linear1 TP Data
Displays the data selected by Parameter 287 [Linear1 TP Sel].
Min/Max:
Comm Scale:
Default:
Lin1 Update Rate
Sets the sample rate for the linear channel on the Multi Device Interface (MDI) feedback Options:
option.
Units:
Linear1 CPR
Specifies the change in Parameter 276 [FB Opt1 Posit] for one revolution of the motor Default:
shaft. This value is used to scale the calculated speed, based on the change in feedback Min/Max:
position. Units are count per motor revolution (CPR).
Comm Scale:
Units:
Output Curr Disp
Displays measured RMS motor current with a resolution of 1/10 amperes.
Default:
Min/Max:
Comm Scale:
Units:
Elapsed Run Time
Displays the total time that drive has been running (inverter power devices active) with a Default:
resolution of 1/10 hour. This parameter is saved in power EE non-volitile memory. The Min/Max:
value in this parameter can be changed (written to) by the user.
Comm Scale:
Units:
Elapsed MWHrs
Displays the total energy the drive has consumed or produced. Calculated from the
Default:
absolute magnitude of the product of motor speed and motor torque (power),
Min/Max:
accumulated over time. This value will increase in both regen and motoring modes of Comm Scale:
operation. This parameter value can be changed (written to) by the user.
Units:
Motor Spd Fdbk
Displays measured motor speed information from the selected feedback device.
Default:
Min/Max:
Comm Scale:
Units:
Motor Speed Ref
Displays the speed reference value, after the limit function. This is the input to the error Default:
Min/Max:
calculator and speed regulator.
Comm Scale:
Units:
Spd Reg PI Out
Displays the output of the speed regulator. This is the input to torque control. A value of Default:
Min/Max:
1.0 represents base Torque of the motor.
Comm Scale:
0
0
1
2
3
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
Reserved
Default
Bit
Reserved
Options
Open Wire
Indicates faults on the Multi Device Interface (MDI).
Bit 8 [Open Wire] indicates an open wire fault.
Reserved
286
Values
Data Type
Name
Description
Read-Write
No.
Linkable
Programming and Parameters
Reserved
3-42
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
0
0
“Zero”
“Zero”
4
“L1 Edge Time” 5
“L1 dEdge”
6
“L1 dTime”
0
-/+32768
x1
2
“1.0 msec”
1
“0.5 msec”
2
“1.0 msec”
CPR
1000
10/100000
x1
Amps
0.0
0.0/9999.9
x 10
Hrs
0.0
0.0/429496736.0
x 10
MWHrs
0.0
0.0/429496736.0
x 10
0 = True
1 = False
“L1 EPR”
“L1 Edge Mode”
“L1 dTheta”
16-bit
Integer
3
4
“1.5 msec”
“2.0 msec”
✓ 32-bit
Integer
RPM
0.0000
-/+14112.0000
Parameter 4 [Motor NP RPM] = 1.0
RPM
0.0000
-/+14112.0000
Parameter 4 [Motor NP RPM] = 1.0
P.U.
0.0000
-/+8.0000
x1
32-bit
Integer
✓ 32-bit
Integer
✓ 32-bit
Integer
Real
Real
Real