Download PowerFlex 700S High Performance AC Drive
Transcript
282 Opt 1 Regis Stat 287 288 289 290 297 298 299 300 301 302 Reserved Reserved Reserved Reserved Reserved Reserved Reserved Found Armed Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 Reserved Default Bit Reserved Options Reserved Displays the registration control status of port 1 on the feedback option card. • Bit 0 [Armed] indicates the when the registration latch has been armed. Bit 1 [Found] indicates that the registration event has triggered the latch. 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 0 = True 1 = False Linear1 Status Default: Linear1 TP Sel Enter or write a value to select Linear Feedback data data displayed in Parameter 288 Options: [Linear1 TP Data]. • Value 0 - Zero displays a value of zero. • Value 1 - HO Edge Time displays the change displays the latency or edge time (the time since the last update of Parameter 276 [FB Opt1 Posit]). • Value 2 - HO dEdge displays the change in Parameter 276 [FB Opt1 Posit] since the last feedback sample. • Value 3 - HO DTime displays the change in time since the last feedback sample Note the sample rate is 10,000 counts per second (10 Mhz). • Value 4 - HO EPR displays the change in edges per motor revolution. This number is the same value in Parameter 290 [Linear1 CPR]. • Value 5 - Edge Mode displays ? • Value 6 - HO dTheta displays the numerator term for speed calculation. This number divided by change in time (TP3) is the calculated per unit speed for the linear feedback sensor. Default: Linear1 TP Data Displays the data selected by Parameter 287 [Linear1 TP Sel]. Min/Max: Comm Scale: Default: Lin1 Update Rate Sets the sample rate for the linear channel on the Multi Device Interface (MDI) feedback Options: option. Units: Linear1 CPR Specifies the change in Parameter 276 [FB Opt1 Posit] for one revolution of the motor Default: shaft. This value is used to scale the calculated speed, based on the change in feedback Min/Max: position. Units are count per motor revolution (CPR). Comm Scale: Units: Output Curr Disp Displays measured RMS motor current with a resolution of 1/10 amperes. Default: Min/Max: Comm Scale: Units: Elapsed Run Time Displays the total time that drive has been running (inverter power devices active) with a Default: resolution of 1/10 hour. This parameter is saved in power EE non-volitile memory. The Min/Max: value in this parameter can be changed (written to) by the user. Comm Scale: Units: Elapsed MWHrs Displays the total energy the drive has consumed or produced. Calculated from the Default: absolute magnitude of the product of motor speed and motor torque (power), Min/Max: accumulated over time. This value will increase in both regen and motoring modes of Comm Scale: operation. This parameter value can be changed (written to) by the user. Units: Motor Spd Fdbk Displays measured motor speed information from the selected feedback device. Default: Min/Max: Comm Scale: Units: Motor Speed Ref Displays the speed reference value, after the limit function. This is the input to the error Default: Min/Max: calculator and speed regulator. Comm Scale: Units: Spd Reg PI Out Displays the output of the speed regulator. This is the input to torque control. A value of Default: Min/Max: 1.0 represents base Torque of the motor. Comm Scale: 0 0 1 2 3 Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 Reserved Default Bit Reserved Options Open Wire Indicates faults on the Multi Device Interface (MDI). Bit 8 [Open Wire] indicates an open wire fault. Reserved 286 Values Data Type Name Description Read-Write No. Linkable Programming and Parameters Reserved 3-42 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 “Zero” “Zero” 4 “L1 Edge Time” 5 “L1 dEdge” 6 “L1 dTime” 0 -/+32768 x1 2 “1.0 msec” 1 “0.5 msec” 2 “1.0 msec” CPR 1000 10/100000 x1 Amps 0.0 0.0/9999.9 x 10 Hrs 0.0 0.0/429496736.0 x 10 MWHrs 0.0 0.0/429496736.0 x 10 0 = True 1 = False “L1 EPR” “L1 Edge Mode” “L1 dTheta” 16-bit Integer 3 4 “1.5 msec” “2.0 msec” ✓ 32-bit Integer RPM 0.0000 -/+14112.0000 Parameter 4 [Motor NP RPM] = 1.0 RPM 0.0000 -/+14112.0000 Parameter 4 [Motor NP RPM] = 1.0 P.U. 0.0000 -/+8.0000 x1 32-bit Integer ✓ 32-bit Integer ✓ 32-bit Integer Real Real Real