Download User Manual
Transcript
THE 88RS CONSOLE SURFACE The 88RS Channel Module Input Filters kHz 7.5 18 8 13 pull FILT 315 31.5 Hz 50 10 240 9 150 80 Channel Module Input Filter section These are 12dB/octave high and low pass filters, with continuously variable frequency ranges from 31.5Hz to 315Hz and 7.5kHz to 18kHz respectively. The filters can be switched into the channel or monitor path independently of the EQ by pulling out the relevant frequency control knob. Dynamics Control Full limiter/compressor and gate/expander facilities are available (each of which can be individually switched in or out of circuit). The expander/gate uses the left hand side controls of the section and the controls for the compressor/limiter are on the right. KEY L/C SC-EQ EXP HYST 25 GAIN 0 5 30 20 6 10 24 THR -25 18 15 15 12 THR pull 20 HN -17 -10 7 pull -40 14 -10 -4 0 8 2 pull -20 30 20 3 50 10 0 pull FAST pull INV .01 RGE 0.2 REL GATE 5 60 2 1 lim RAT pull FAST 0.2 .01 3s REL AUTO 3s Channel Module Dynamics section The expander/gate has rotary controls for a 0-60dB gate depth range, a +15 to -65dB threshold (using the integrated -40dB switch), release time from 10ms to 3s, a switchable attack time of 500ms (RGE knob in) or 50ms (RGE knob pulled out) and variable hysteresis. The hysteresis control sets the difference in threshold for signals that are rising or falling in level. Signals that are rising in level turn on when the level reaches the threshold level plus the hysteresis value. Signals that are falling in level turn off at the lower threshold level. Raising the threshold for rising signals prevents noise turning the gate on, while allowing a lower threshold for falling signals to prevent reverb signal ‘tail’s being prematurely gated. For example, if the threshold is set at - 50 and the hysteresis is set at 10, the signal level would have to rise above -40dB before the channel turns on and the channel would remain on until the signal level fell below -50dB. The control allows up to 25dB of hysteresis. Turning the hysteresis control fully counter-clockwise switches the gate off and the 2:1 expander on. Pulling out the release control inverts the key (control) signal to the gate, turning it into a “ducker”. This feature is normally used with an external key. When gating, a signal above threshold level on the key input allows signal to pass; when ducking a signal above threshold level on the key input causes the gain of the channel signal to be reduced by the amount set on the depth (RGE) control. Switches are provided for the external key input and for inserting the EQ into the side-chain, for frequency conscious gating or compression (eg de-essing). The external key input is accessed from the patchbay. Issue 3 88RS User Manual 3:5