THE 88RS CONSOLE SURFACE
The 88RS Channel Module
Input Filters
kHz 7.5
18
8
13
pull
FILT
315
31.5
Hz
50
10
240
9
150
80
Channel Module
Input Filter section
These are 12dB/octave high and low pass filters, with
continuously variable frequency ranges from 31.5Hz to
315Hz and 7.5kHz to 18kHz respectively.
The filters can be switched into the channel or monitor path
independently of the EQ by pulling out the relevant
frequency control knob.
Dynamics Control
Full limiter/compressor and gate/expander facilities are
available (each of which can be individually switched in or
out of circuit). The expander/gate uses the left hand side
controls of the section and the controls for the
compressor/limiter are on the right.
KEY
L/C
SC-EQ
EXP
HYST 25
GAIN
0
5 30
20
6
10 24
THR
-25 18
15
15
12
THR
pull
20 HN
-17 -10
7
pull
-40
14
-10 -4
0
8
2
pull
-20
30
20
3
50
10
0
pull
FAST
pull
INV
.01
RGE
0.2
REL
GATE
5
60 2
1
lim
RAT
pull
FAST
0.2
.01
3s
REL AUTO
3s
Channel Module
Dynamics section
The expander/gate has rotary controls for a 0-60dB gate
depth range, a +15 to -65dB threshold (using the
integrated -40dB switch), release time from 10ms to 3s, a
switchable attack time of 500ms (RGE knob in) or 50ms
(RGE knob pulled out) and variable hysteresis.
The hysteresis control sets the difference in threshold for
signals that are rising or falling in level. Signals that are
rising in level turn on when the level reaches the threshold
level plus the hysteresis value. Signals that are falling in level
turn off at the lower threshold level. Raising the threshold for
rising signals prevents noise turning the gate on, while
allowing a lower threshold for falling signals to prevent
reverb signal ‘tail’s being prematurely gated. For example,
if the threshold is set at - 50 and the hysteresis is set at 10,
the signal level would have to rise above -40dB before the
channel turns on and the channel would remain on until the
signal level fell below -50dB. The control allows up to 25dB
of hysteresis.
Turning the hysteresis control fully counter-clockwise
switches the gate off and the 2:1 expander on.
Pulling out the release control inverts the key (control) signal
to the gate, turning it into a “ducker”. This feature is
normally used with an external key. When gating, a signal
above threshold level on the key input allows signal to pass;
when ducking a signal above threshold level on the key
input causes the gain of the channel signal to be reduced by
the amount set on the depth (RGE) control.
Switches are provided for the external key input and for
inserting the EQ into the side-chain, for frequency
conscious gating or compression (eg de-essing). The
external key input is accessed from the patchbay.
Issue 3
88RS User Manual 3:5