Transcript
ST-37RS – user's manual After weather control is enabled the valve set-point parameter is calculated based on the heating curve. By changing this parameter you can decrease or increase all the weather control settings. 9. Room regulator To regulator ST-37 or valve module ST-61 a room regulator can be attached, assigned to mixing valve control. After its activation, the valve is controlled by a room regulator. The user can select the type of room regulator: ➔ TECH regulator (RS communication) Every change in room temperature causes a corresponding change in the preset temperature of of the mixing valve (see: Valve 1, 2 – Chapter 2 no. 1 – p. 11 and 12). In the case of connecting TECH regulator (connection to socket on boiler controller), the user has the possibility to control and change the preset CH and Usable Hot Water temperature, as well as of the mixing valve; any boiler controller alarms are also displayed. When cooperating with the mixing valve, the user has the opportunity to view the current external temperature during the main screen view with valve parameters. ➔ two-state (standard regulator connected with the main controller - ST-37) Heating the apartment to the preset temperature will cause reduction in the set temperature of the valve by the value of the parameter of room temperature reduction (see: Valve 1, 2 – Chapter 2 no. 1 – p.13). ➔ valve regulator (standard regulator connected to valve module - ST-61) Heating the apartment to the preset temperature will cause reduction in the set temperature of the valve by the value of the parameter room temperature reduction (see: Valve 1, 2 – Chapter 2 no. 1 – p.13). Heating the room regulator in this case will not have effect on the boiler's operation. In the whole set (boiler controller along with valves) it is possible to use only one TECH room regulator, the remaining may only be standard (twostate). NOTE: N o e x t e r n a l v o l t a g e c a n b e c o n n e c t e d t o t h e o u t p u t o f the room regulator. 10. Return protection This function permits setting the boiler protection against too cool water returning from the main circulation, which could cause lowtemperature boiler corrosion. The return protection operates in such a way that when the temperature is too low, the valve is closed, until the short circulation of the boiler reaches the appropriate temperature. This function also protects the boiler against dangerously high temperature of return in 14