EOAP
Method B: Perform steps a. through d. to update both EOAPs at the same
time. This method is NOT recommended.
a. Enter the following command:
act-oap-config:oap=all
After successful completion of this command, the system returns the
following output:
rlghncxa03w 00-06-07 11:34:04 EST
ACT-OAP-CONFIG: MASP A - COMPLTD
Rel 26.0.0
b. Wait 15 minutes, then enter either the rept-stat-seas (if only the
SEAS feature is on) or rept-stat-lsms (if only the LNP feature is
on) commands to make sure that there are no alarms for the EOAPs.
If both the SEAS and LNP features are on, then enter both commands
to verify that there are no alarms for the EOAPs. This is an example
of the possible output:
rept-stat-seas
rlghncxa03w 00-06-04 15:59:06 EST Rel 26.0.0
SEAS Subsystem Report
IS-NR
Active
-------SEAS Interfaces Configured = 2 Interfaces IS-NR = 2
GPL
PST
SST
AST
--------------------------------------------------------------------SEAS SYSTEM
IS-NR
Active
----TDM Port
4
IS-NR
Active
----TDM Port
10
IS-NR
Active
----OAP
A
250-001-000
IS-NR
Active
----OAP
B
250-001-000
IS-NR
Active
----X.25 Link
A1
IS-NR
Active
----X.25 Link
B1
IS-NR
Active
----SEAS SYSTEM
OAP A
OAP B
X25 Link A1
X25 Link A2
X25 Link B1
X25 Link B2
X25
X25
X25
X25
A1
A1
B1
B1
PVCs
PVCs
PVCs
PVCs
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
ALARM
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
=
=
=
=
=
=
=
IS-NR
OOS-MT
IS-NR
OOS-MT
=
=
=
=
1,2,3
--1,2,3
---
X25 A2 PVCs IS-NR
X25 A2 PVCs OOS-MT
X25 B2 PVCs IS-NR
X25 B2 PVCs OOS-MT
Command Completed.
=
=
=
=
1,2,3
--1,2,3
---
910-4601-01 Revision D, May 2005
No
No
No
No
No
No
No
Alarms.
Alarms.
Alarms.
Alarms.
Alarms.
Alarms.
Alarms.