Download Technical Manual TNC 360
Transcript
Connect storage oscilloscope to tachometer of servo-amplifier of X axis. Enter following program in "PROGRAMMING AND EDITING" operating mode: LBL 1 X 1001) R0 F MAX X 0 R0 F MAX CALL LBL 1 REP 100/100 Press machine START button in the "PROGRAM RUN/FULL SEQUENCE" operating mode. Machine runs. MP1520: Increase entry value until the position is clearly traversed when approaching. The overshoot can also be observed in the actual value display. Tacho voltage U [V] t [ms] MP1520: Reduce the entry value until the position is no longer traversed. U [V] t [ms] Check axes Y, Z and IV and correct MP1530, if necessary. 1) Program the traverse paths for the axis concerned as large as possible. 8/95 TNC 360 16 Commissioning and Start-up Procedure 4-241