Technical data
LS600V - LS6000
6N
Type
Model
Splitting force
Log length
Log diameter
Stroke
60 kN (6 t)
max. 1050 mm
min. 120 mm – max. 300 mm
| 500 mm
Hydraulic oil (max.)
Hydraulic pressure
Electric motor performance (power consumption)
Power supply
4.5 litres
20 MPa (200 bar)
P1 3.0 kW S6 (4 min/6 min)
230 V~ 50 Hz, 13 A time-lag
Weight
approx. 100 kg
Possible problems
Problem
Possible cause
Remedy
Logs are not being split Ÿ The log is not positioned correctly.
Ÿ Reposition the log correctly.
properly
Ÿ The log exceeds the maximum dimensions Ÿ Cut the log to the required dimensions.
(insufficient
splitting
or the wood is too hard for the performance
performance).
of the machine.
Ÿ Splitting blade does not split log.
Ÿ Sharpen splitting blade, check for burrs or
notches.
Ÿ Hydraulic pressure too low.
Ÿ Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Ÿ Release rods bent (hydraulic tappet not Ÿ Arrange for manufacturer or authorised company
to adjust the rods.
quite pressed in).
Ÿ Incorrect connecting lead (longer than 10 m Ÿ Use the correct connecting lead.
or too small cable cross-section).
Splitting column moves Ÿ Air in the circuit.
Ÿ Check the oil level and add more oil if necessary.
unsteadily or with strong Ÿ Splitting column not sufficiently lubricated or Ÿ Lubricate splitting column or oil with
vibrations.
environmentally friendly spray oil.
oiled.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Splitting column does not Ÿ Hydraulic pump defective.
Ÿ To correct the problem, refer to the manufacturer
move in.
or other approved service centre.
Motor starts, but splitting Ÿ Motor turns in wrong direction
Ÿ Check the motor direction
column does not move in.
To correct the problem, refer to the manufacturer
or other approved service centre.
Motor will not start.
Ÿ No electrical power.
Ÿ Check the fuse.
Ÿ Connection cable defective.
Ÿ Replace the connection cable or have it checked
by an electrician.
Ÿ Electric motor defective.
Ÿ To correct the problem, refer to the manufacturer
or other approved service centre.
13