Download LabOne Programming Manual
Transcript
4.4. LabOne Python API (ziPython) Command Reference | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | set(...) set( (ziDAQSweeper)arg1, (str)arg2, (float)arg3) -> None : Sweep Parameters Path name Type Description sweep/device string Device that should be used for the parameter sweep, e.g. 'dev99'. sweep/start double Sweep start frequency [Hz] sweep/stop double Sweep stop frequency [Hz] sweep/gridnode string Path of the node that should be used for sweeping. For frequency sweep applications this will be e.g. 'oscs/0/freq'. The device name of the path can be omitted and is given by sweep/device. sweep/loopcount int Number of sweep loops (default 1) sweep/endless int Sweep endless (default 0) 0 = endless off, use loopcount, 1 = endless on, ignore loopcount. sweep/samplecount int Number of samples per sweep. sweep/settling/time double Settling time before measurement is performed. sweep/settling/tc double Settling time in time constant units 5 ~ low precision 15 ~ medium precision 50 ~ high precision sweep/settling/inaccuracy int Demodulator filter settling inaccuracy defining the wait time between a sweep parameter change and recording of the next sweep point. Typical inaccuracy values: 10m for highest sweep speed for large signals, 100u for precise amplitude measurements, 100n for precise noise measurements. Depending on the order the settling accuracy will define the number of filter time constants the sweeper has to wait. The maximum between this value and the settling time is taken as wait time until the next sweep point is recorded. sweep/xmapping int Sweep mode: 0 = linear, 1 = logarithmic. sweep/scan int Scan type: 0 = sequential, 1 = binary, 2 = bidirectional, 3 = reverse. sweep/bandwidth double Fixed bandwidth [Hz], 0 = Automatic calculation. sweep/bandwidthcontrol int Sets the bandwidth control mode, (default 2): 0 = Manual (user sets bandwidth and order), 1 = Fixed (uses fixed bandwidth value), 2 = Auto (calculates best bandwidth value) Equivalent to the obsolete bandwidth = 0 setting. sweep/order int Defines the filter roll off to use in Fixed bandwidth selection. Valid values are between 0 (6 dB/octave) and 8 (48 dB/octave). An order of 0 triggers a read-out of the order from the selected demodulator. sweep/maxbandwidth double Maximal bandwidth used in auto bandwidth mode in [Hz]. The default is 1.25MHz. sweep/omegasuppression double Damping in [dB] of omega and 2-omega LabOne Programming Manual Revision 31421 Zurich Instruments 97