Download User Manual

Transcript
Chapter 3
Configuration and Operation
Table 5.
Commands Menu (continued)
Menu Item
Description
Enable Comm Status
Allows start-up of the application with only one functioning network between the two hosts.
(PPRS anticipates two functional networks when it starts.) Use this command only when one of
two installed networks is not functional. When you select this option, Enabled appears in the
Override Communication Status field of the PPRS Main window.
If one of the networks fails while PPRS is running, a pop-up communication warning window
appears periodically (three times per polling period). To stop this warning window from
continuing, select this command.
Enable Failover
Enables the local host to failover (if it is the primary host) or takeover (if it is the backup host)
when required. When you select this option, Enabled appears in the Failover Command Status
field of the PPRS Main window.
Disable Failover
Disables the Failover/Takeover option. When you select this option, Disabled appears in the
Failover Command Status field of the PPRS Main window to indicate that the host is not in
redundant mode.
Manual Failover
Causes a manual failover to the backup host. This command can be used for testing the PPRS
application and for maintenance purposes.
Enable Warning Msg
Enables warning messages to pop-up when Picture Perfect reaches critical limits.
Disable Warning Msg
Disables subsequent pop-up warning messages.
31