The instruments used during the External Calibration and External Performance Verification on any J750E tester should be checked for this certification to be current by the Test Engineer who is performing the Calibration. Since the instruments are calibrated to the NIST standard and are traceable, all measurements made using the accuracy of these instruments are now traceable to the NIST standard. CAL-CUB Calibration Process:This section describes the CAL-CUB external calibration process. The CAL-CUB is used as the central reference standard for the entire system. Its calibration circuitry accurately sources, and measures voltages and currents. After External Calibration, the CAL-CUB voltage source, current source and metering circuits are distributed via the Cal-DIB to all channels and provides parametric measurement for all options in the J750E tester and this is how Internal Calibration is performed. Also located on the CAL-CUB board is the SLI Super Linear Integrator circuit, which is a super accurate programmable TDR pulse generator that is used via the Cal-DIB for the purpose of Calibrating all PE channel edges to be within the hardware published specification. This is referred to as AC calibration and is performed within the Internal Calibration. External Performance Verification External Performance Verification is run to verify the CAL-CUB internal reference circuitry against the external references to guarantee that the internal hardware is at its maximum accuracy and to check the tester against the design specifications. External Performance Verification performs the following two tests: • Voltage and Current Verification • Master Clock Frequency Verification Voltage and Current Verification:External Performance Verification uses the same instrumentation set up as the External Calibration. External Performance Verification is used to verify all points within each calibrated voltage and current range and metering circuit using the Calibration correction factors stored in the flash memory. But the values read by the meter is only compared to its limit specification for pass or fail test. After the completion of the Voltage and Current Verification, the checker goes directly to the Master Clock Frequency Verification part of the checker. This requires connecting a cable from the Cal-DIB to the frequency counter and then running the program. The meter output is then compared to the program limits. Master Clock Frequency Verification:The CAL-CUB board is equipped with a 200MHz Hermetic Sealed Hybrid Oscillator that is divided by 2 to generate the 100MHz system clock used to control the J750E tester timing. This 100MHz is verified with the use of a Frequency Counter connected to the IEEE bus interface. The Master Clock Specification: • Frequency: 100 MHz • Accuracy: ±15 ppm +5 ppm/year. 4-8 J750E-512 Pin Test System Service Reference Manual