Download User Manual - Temperature & Process Instruments, Inc.
Transcript
Probe for measuring the ionization current With this special probe it is possible to measure the ionization current of a boiler and check its value depending on the boiler’s technical features. Calibration certificate The instrument is calibrated by comparing to National Calibration Standards provided by a Metrology Lab., certified periodically by internationally recognized laboratories. A calibration certificate is provided with each and every instrument where every parameter is accompanied by the relevant nominal value, measured value, permissible error tolerances and measured error. 1 2 Electromagnetic compatibility The instrument was designed to comply with Council Directive 2004/108/EC governing electromagnetic compatibility. 2.3 Measurement Ranges and Accuracies MEASUREMENT SENSOR RANGE RESOLUTION O2 Electrochemic al sensor 0 .. 25.0% vol 0.1% vol CO W ith low sensitivity to H2 Electrochemic al sensor 0 .. 8000 ppm 1 ppm ±20 ppm 0 .. 400 ppm ±5% measured val ue 201 .. 4000 ppm ±10% meas ured value 4001 .. 8000 ppm NO Electrochemic al sensor 0 .. 5000 ppm 1 ppm ±5 ppm ±5% measured val ue NOx Calculated CO2 Calculated 0 .. 99.9% vol Air temperatur e Pt100 s ens or -20.0 .. 120.0 °C 0.1 °C ±0.5 °C Flue gas temper ature TcK sens or -100.0 .. 1250.0 °C 0.1 °C ±0.5 °C ±0.5% meas ured value Pressure (draft & differential) Piezoel ectric sens or -4.014 .. 80.292 inH2O 0.004 inH 2O Differential temp erature Calculated 0 .. 1250.0 °C 0.1 °C (1) 3 ACCURACY ±0.2% vol 0 .. 100 ppm 101 .. 5000 ppm 4 0.1% vol (4) Air index Calculated 0.00 .. 9.50 0.01 Excess air Calculated 0 .. 850 % 1% Stack loss Calculated 0.0 .. 100.0 % 0.1 % Efficiency Calculated 0.0 .. 100.0 % 0.1 % Efficiency (condensing) Calculated 0.0 .. 120.0 % 0.1 % Smoke index External instrument 0 .. 9 (2) 0 .. 10 0 °C 101 .. 1250 °C (3) ±1% measured val ue -4.014 .. 0.806 inH2O ±0.008 inH2O -0.802 .. 0.802 i nH2O ±1% measured val ue 0.806 .. 0.292 inH2 O 5 6 All data relative to concentration accuracies are referred to an instrument operating at a constant temperature within the correct operating range (-5°C .. +45°C), being in operation for at least 15 minutes, powered by its internal battery and after completion of auto-zero procedure. Notes: (1) The maximum CO 2 value displayed depends on the type of fuel. (2) Stated precision includes error of the external sensor RTD Pt100 class A DIN 43760 (1980). (3) Stated precision includes error of the external sensor type K thermocouple class 1 IEC584. (4) Pressures greater than 300 inH2O may permanently damage sensors or impair their characteristics. 7 8 K8000 000 00EJ 02 065 0A0 17 051 2 11