Download User Manual - Temperature & Process Instruments, Inc.

Transcript
Probe for measuring the ionization current
With this special probe it is possible to measure the ionization current of a boiler and check its value depending
on the boiler’s technical features.
Calibration certificate
The instrument is calibrated by comparing to National Calibration Standards provided by a Metrology Lab.,
certified periodically by internationally recognized laboratories.
A calibration certificate is provided with each and every instrument where every parameter is accompanied by the
relevant nominal value, measured value, permissible error tolerances and measured error.
1
2
Electromagnetic compatibility
The instrument was designed to comply with Council Directive 2004/108/EC governing electromagnetic
compatibility.
2.3 Measurement Ranges and Accuracies
MEASUREMENT
SENSOR
RANGE
RESOLUTION
O2
Electrochemic al sensor
0 .. 25.0% vol
0.1% vol
CO
W ith low sensitivity to
H2
Electrochemic al sensor
0 .. 8000 ppm
1 ppm
±20 ppm
0 .. 400 ppm
±5% measured val ue
201 .. 4000 ppm
±10% meas ured value 4001 .. 8000 ppm
NO
Electrochemic al sensor
0 .. 5000 ppm
1 ppm
±5 ppm
±5% measured val ue
NOx
Calculated
CO2
Calculated
0 .. 99.9% vol
Air temperatur e
Pt100 s ens or
-20.0 .. 120.0 °C
0.1 °C
±0.5 °C
Flue gas temper ature
TcK sens or
-100.0 .. 1250.0 °C
0.1 °C
±0.5 °C
±0.5% meas ured value
Pressure
(draft & differential)
Piezoel ectric sens or
-4.014 .. 80.292 inH2O
0.004 inH 2O
Differential temp erature
Calculated
0 .. 1250.0 °C
0.1 °C
(1)
3
ACCURACY
±0.2% vol
0 .. 100 ppm
101 .. 5000 ppm
4
0.1% vol
(4)
Air index
Calculated
0.00 .. 9.50
0.01
Excess air
Calculated
0 .. 850 %
1%
Stack loss
Calculated
0.0 .. 100.0 %
0.1 %
Efficiency
Calculated
0.0 .. 100.0 %
0.1 %
Efficiency
(condensing)
Calculated
0.0 .. 120.0 %
0.1 %
Smoke index
External instrument
0 .. 9
(2)
0 .. 10 0 °C
101 .. 1250 °C
(3)
±1% measured val ue -4.014 .. 0.806 inH2O
±0.008 inH2O
-0.802 .. 0.802 i nH2O
±1% measured val ue 0.806 .. 0.292 inH2 O
5
6
All data relative to concentration accuracies are referred to an instrument operating at a constant temperature
within the correct operating range (-5°C .. +45°C), being in operation for at least 15 minutes, powered by its
internal battery and after completion of auto-zero procedure.
Notes: (1) The maximum CO 2 value displayed depends on the type of fuel.
(2) Stated precision includes error of the external sensor RTD Pt100 class A DIN 43760 (1980).
(3) Stated precision includes error of the external sensor type K thermocouple class 1 IEC584.
(4) Pressures greater than 300 inH2O may permanently damage sensors or impair their characteristics.
7
8
K8000 000 00EJ 02 065 0A0 17 051 2
11