Download ecoTEC plus
Transcript
5 Installation 5.7 1. Installing the discharge pipe on the expansion relief valve Install the discharge pipe for the expansion relief valve so that it does not interfere with the removal and fitting of the lower section of the condensate trap. 5.8.2 1. 2. 3. 3. Replacing the connection piece for the air/flue pipe as required Replace the connection piece for the air/flue pipe as required. The product-specific standard equipment is listed under Technical data. Remove the connection piece for the air/flue pipe. (→ Page 16) Alternatives 1 / 2 ▶ If required, install the connection piece for the air/flue pipe, 80/125 mm diameter. (→ Page 16) Alternatives 2 / 2 ▶ If required, install the connection piece with offset for the air/flue pipe, 60/100 mm diameter. (→ Page 16) 5.8.2.1 Removing the connection piece for the air/flue pipe 3. 2. 3. 4. 5. Install the discharge pipe as shown (do not shorten). Make sure that the end of the pipe is visible. Ensure that discharged water or steam cannot cause injury to persons or damage to electronic components. Ensure the discharge pipe work is installed, routed and terminated correctly to minimise the risk of freezing up. 5.8 Flue gas installation 5.8.1 Installing and connecting the flue pipe 1. 2. You can find out which flue pipes may be used by consulting the enclosed flue pipe installation manual. Observe the information on positioning the opening for the flue pipe. This information can be found in the appendix. Conditions: Installation in damp rooms ▶ You must connect the product to a room-sealed air/flue gas installation. The combustion air must not be taken from the installation site. 2. 1. 2. 3. Mineral-oil-based greases can damage the seals. ▶ 3. 16 Instead of grease, use only water or commercially available soft soap to aid installation. Insert a screwdriver into the slot between the measuring stub pipes. Press the screwdriver carefully down (1.). Turn the connection piece anticlockwise (2.) as far as it will go and then remove it by pulling it upwards (3.). 5.8.2.2 Installing the connection piece for the air/flue pipe, 80/125 mm diameter 1. 2. Caution. Risk of poisoning due to escaping flue gas. 1. 3. Remove the connection piece for the air/flue pipe. (→ Page 16) Insert the alternative connection piece. In doing so, pay attention to the latching lugs. Turn the connection piece clockwise until it clicks into position. 5.8.2.3 Installing the connection piece with offset for the air/flue pipe, 60/100 mm diameter 1. Remove the connection piece for the air/flue pipe. (→ Page 16) Install the flue pipe using the installation manual. Installation and maintenance instructions ecoTEC plus 0020209591_00