Download 1.2 Before using - HF Inverter Polska
Transcript
E2000 Linear speed L***. If it exceeds 999, add a decimal point to it. If it exceeds 9999, add two decimal points to it, and the like. PID given value o*.* PID feedback value b*.* Yarn length * center frequency *.** output power *.* output torque *.* Note: when count value is displayed and it exceeds 9999, only 4 digits are displayed and add a decimal point to it, i.e. 12345 is displayed in the form of 1234. . Setting range: 0: Frequency/function-code 1: Keypad jogging 2: Target rotary speed Mfr’s value: 4: PN voltage F132 Display items of stop 8: PID feedback value 0+2+4=6 16: Temperature 32: Count values 64: PID given value 128: Yarn length 256: Center frequency 512: Setting torque F133 Drive ratio of driven system Setting range: 0.10~200.0 Mfr’s value: 1.00 F134 Transmission-wheel radius 0.001~1.000 (m) Mfr’s value: 0.001 ·Calculation of rotary speed and linear speed: For example, If inverter’s max frequency F111=50.00Hz, numbers of motor poles F804=4, drive ratio F133=1.00, transmission-shaft radius R=0.05m, then Transmission shaft perimeter: 2πr =2×3.14×0.05=0.314 (meter) Transmission shaft rotary speed: 60× operation frequency/ (numbers of poles pairs × drive ratio) =60×50/ (2×1.00) =1500rpm Endmost linear speed: rotary speed × perimeter=1500×0.314=471(meters/second) F136 Slip compensation Setting range: 0~10 Mfr’s value: 0 · Under V/F controlling, rotary speed of motor rotor will decrease as load increases. Be assured that rotor rotate speed is near to synchronization rotary speed while motor with rated load, slip compensation should be adopted according to the setting value of frequency compensation. Note: during the process of speed track, slip compensation function is invalid. After speed track is finished, this function is valid. Setting range: 0: Linear compensation; 1: Square compensation; Mfr’s value: 0 F137 Modes of torque compensation 2: User-defined multipoint compensation 3: Auto torque compensation 4: V/F separation F138 F139 Linear compensation Setting range: 1~20 Square compensation Setting range: 1: 1.5 2: 1.8 3: 1.9 4: 2.0 5~6: Reserved When F106=2, the function of F137 is valid. ·50· Mfr’s value: subject to inverter model Mfr’s value: 1