Electrical Connections
All units are equipped with an electrical wiring schematic inside the electrical panel. If one is not
provided, please contact the factory at 1-800-432-8387 to obtain one.
Warning!
Disengage main power disconnect before attempting
installation.
Power connections supplied to the unit must be in accordance with
national and local electric code.
• Use an approved flexible conduit to supply power to the heat pump where appropriate to code.
• Electrical Grounding must be supplied congruent to national and local code.
• If the unit is installed within 15 feet of the pool, the National Electric Code requires the use of Ground
Fault Interrupter (GFI) circuit protection on all installations regardless of their location.
• An outdoor waterproof disconnect should be mounted adjacent to the heat pump for service safety.
• Refer to charts below for electrical ratings / recommendations:
Model /
Type
Volts
Hz
Phase
Compressor
Nom. Amps
Compressor
LRA
HP-4
HP-5
Model /
Type
Operating Specs
230
60
1
19.9A
115A
Operating Specs
Volts
Hz
Phase
Compressor
Nom. Amps
Compressor
LRA
Fan Motor
RLA
Fan Motor
HP
Minimum
Circuit
Ampacity
230
60
1
19.9A
115A
1.7A
Fan Motor RLA
1.7A
Fan Motor HP
¼
Minimum Circuit
Ampacity
30
Max Fuse
30A
Max Fuse
30A
Volts
Hz
Phase
Compressor
Nom. Amps
Compressor
LRA
230
60
1
Volts
Hz
Phase
Compressor
Nom. Amps
Compressor
LRA
Fan Motor
RLA
Fan Motor
HP
Minimum
Circuit
Ampacity
230
60
1
PE-42
27.9A
129A
Fan Motor RLA
2.9A
Fan Motor HP
½
Minimum Circuit
Ampacity
40
Max Fuse
50A
PE-52
Max Fuse
20
¼
30
27.9A
129A
3.3A
½
40
50A