Download Parameters MICROMASTER 430 - Service, Support
Transcript
Issue 08/02 P1035[3] Parameters BI: Enable MOP (UP-command) CStat: CT P-Group: COMMANDS Datatype: U32 Active: first confirm Unit: QuickComm. No Min: Def: Max: 0:0 19:13 4000:0 Level: Min: Def: Max: 0:0 19:14 4000:0 Level: Min: Def: Max: -650.00 5.00 650.00 Level: 3 Defines source for motor potentiometer setpoint increase frequency. Index: P1035[0] : 1st. Command data set (CDS) P1035[1] : 2nd. Command data set (CDS) P1035[2] : 3rd. Command data set (CDS) Common Settings: 722.0 = Digital input 1 (requires P0701 to be set to 99, BICO) 722.1 = Digital input 2 (requires P0702 to be set to 99, BICO) 722.2 = Digital input 3 (requires P0703 to be set to 99, BICO) 722.3 = Digital input 4 (requires P0704 to be set to 99, BICO) 722.4 = Digital input 5 (requires P0705 to be set to 99, BICO) 722.5 = Digital input 6 (requires P0706 to be set to 99, BICO) 722.6 = Digital input 7 (via analog input 1, requires P0707 to be set to 99) 722.7 = Digital input 8 (via analog input 2, requires P0708 to be set to 99) 19.D P1036[3] = MOP up via BOP BI: Enable MOP (DOWN-command) CStat: CT P-Group: COMMANDS Datatype: U32 Active: first confirm Unit: QuickComm. No 3 Defines source for motor potentiometer setpoint decrease frequency. Index: P1036[0] : 1st. Command data set (CDS) P1036[1] : 2nd. Command data set (CDS) P1036[2] : 3rd. Command data set (CDS) Common Settings: 722.0 = Digital input 1 (requires P0701 to be set to 99, BICO) 722.1 = Digital input 2 (requires P0702 to be set to 99, BICO) 722.2 = Digital input 3 (requires P0703 to be set to 99, BICO) 722.3 = Digital input 4 (requires P0704 to be set to 99, BICO) 722.4 = Digital input 5 (requires P0705 to be set to 99, BICO) 722.5 = Digital input 6 (requires P0706 to be set to 99, BICO) 722.6 = Digital input 7 (via analog input 1, requires P0707 to be set to 99) 722.7 = Digital input 8 (via analog input 2, requires P0708 to be set to 99) 19.E P1040[3] = MOP down via BOP Setpoint of the MOP CStat: CUT P-Group: SETPOINT Datatype: Float Active: Immediately Unit: Hz QuickComm. No 2 Determines setpoint for motor potentiometer control (P1000 = 1). Index: P1040[0] : 1st. Drive data set (DDS) P1040[1] : 2nd. Drive data set (DDS) P1040[2] : 3rd. Drive data set (DDS) Note: If motor potentiometer setpoint is selected either as main setpoint or additional setpoint, the reverse direction will be inhibited by default of P1032 (inhibit reverse direction of MOP). To re-enable reverse direction, set P1032 = 0. Parameter List MICROMASTER 430 6SE6400-5AF00-0BP0 87