Configuration
Access
XBT Function
Parameters
Values
A
F31
RESOL Sensor resolution
Units: µm
A
F32
VMAX Maximum velocity
Units: mm/mn
F33
F34
F35
USER UNITS
. UPUL Length
. UPUV Velocity
. UPUA Acceleration
Units: µm, mm, cm, dm, m
Units: mm/mn, cm/mn, dm/mn, m/mn
Units: mm/s2, cm/s2, dm/s2, m/s2
A
F36
F37
XMAX Higher Soft Stop
XMIN Lower Soft Stop
C
F38
F39
ACCE Acceleration
DECE Deceleration
B
F40
TYPEPO Type of reference set-up
1 = Short cam + Marker
2 = Cam
3 = Long cam to zero + Marker
B
F41
VMAN Manual mode velocity
Limits: 1 mm/mn and VMAX
C
B
F42
F43
VSTOP Stopped velocity
TSTOP Stop time-out
Limits: 1 mm/mn and VMAX
Units: 10 ms Limits: 65535
C
F44
TW Target window
Limits: 1 µm and (XMAX-XMIN)/2
C
F45
DMAX Max. position deviation
Limits: 1 µm and XMAX-XMIN
B
F46
UMAX Speed drive level for VMAX
Units: Volts
Limits: 1.00 and 9.00
B
F47
F48
SERVO POSITION:
. KPOS Position gain
. LIMV Velocity limit
. KV Feedforward factor
Units: 1/s
Units: % Vmax
Units: Volts
Limits: 1.00 and 32.00
Limits: 5 and 20
Limits: 0 and 100
MDMAX DMAX divert mask
NDMAX DMAX divert step
Y = YES N = NO
Limits: 0 and 253
MSTOP VSTOP divert mask
NSTOP VSTOP divert step
Y = YES N = NO
Limits: 0 and 253
MTW TW divert mask
NTW TW divert step
Y = YES N = NO
Limits: 0 and 253
TSYN Synchronization time-out
MSYN Synchronization divert mask
NSYN Synchronization divert step
Units: 10 ms
Limits: 1 and 65535
Y = YES N = NO
Limits: 0 and 253
MCPUF CPUF divert mask
NCPUF CPUF divert step
Y = YES N = NO
Limits: 0 and 253
NBWN Nbr. of stored WN
Limits: 0 and 100
A
F49
B
C
F50
F51
*
B
C
F52
F53
*
B
C
F54
F55
*
C
B
C
F56
F57
F58
*
B
B
F59
F60
*
A
*
*
*
*
*
*
*
Limits: 0.1 and 1000.0
F
Access: A = Modify in the configuration, B = A + Modify with XBT terminal, C = B + Modify by AXM program.
* Not relevant to TSX AXM 162 module.
6/7