Download aemc_instruments_jm8..

Transcript
2000A RANGE
Primary current
Ø=2.52" (64 mm)
Cable max.
Accuracy %
Phase shift
1.97 x 5.31" (50 x 135 mm) or
2.52 x 3.94" (64 x 100 mm)
Bus Bar max.
100
A
1.5%
1.5°
400A
2000A
0.75%
0.75°
0.5%
0.5°
Drop Test: 1 m (IEC 68-2-32)
Overload: 2400A for 10 mn
Mechanical Shock: 100 g (IEC 68-2-27)
Ampere Second Product: 50 A.s
Vibration: 10/55/10 Hz, 0.15 mm (IEC 68-2-6)
Polycarbonate Material:
Handles: 10% fiberglass charged
polycarbonate UL 94 V0
3000A RANGE
Primary current
Accuracy %
Phase shift
150
A
1.5%
1.5°
600A
3000A
0.75%
0.75°
0.5%
0.5°
Load Impedance: 0.4Ω
P1
Overload: 3600A for 10 mn
P2
Colors: Dark gray handles with red jaws
Accuracy: Per IEC 185-26-27
Class 0.5 (10VA) from 48 to 1000 Hz
SAFETY SPECIFICATIONS
Load Impedance: ≤ 2Ω
Working Voltage: 600V AC
Black
S1
Influence of Adjacent Conductor:
< 0.005A/A AC
S2
Influence of Conductor in Jaw Opening:
1.5% ± 0.2A on 1000:5 range
1% ± 0.2A on 2000:5 range
1% ± 0.2A on 3000:5 range
ELECTRICAL SPECIFICATIONS
Current Range:
1 to 1000A AC continuous cycle
1 to 2000A AC continuous cycle
1 to 2400A AC continuous cycle for the full
temperature range.
(3000 A if temperature <35º C or 95º F)
Output Signal:
5mA AC/A AC (5A at 1000A)
2.5mA AC/A AC (5A at 2000A)
www.
Quality AEMC
Products
Online
1.666mA
AC/A AC
(5A at:
at 3000A)
Weight: 2.65 lbs. (1200 g)
Electrical:
Double insulation or reinforced insulation between
primary or secondary and outer case of handle
upon IEC 1010-2-32
Common Mode Voltage:
600V Category III, Pollution: 2
Common Mode Voltage: 600V AC
Red
Transformation Ratio:
1000:5, 2000:5 -3000:5
Dimensions:
4.72 x 12.40 x 1.9" (120 x 315 x 48 mm)
Output:
Two standard safety banana jacks (4mm)
Frequency Range: 30 to 1500 Hz; current
derating above 1500Hz for continuous use
4.72"
(120 mm)
Jaws: ABS UL 94 V2
Ampere Second Product: 80 A.s
(*Reference conditions: 23°C±3°K, 20 to 85%
RH, 45 to 65 Hz, external magnetic field < 40
A/m, no DC component, no external current
carrying conductor, test sample centered.)
1.89"
(48 mm)
Envelope Protection: IP 20 (IEC 529)
Load Impedance: 0.2Ω
Accuracy: Per IEC 185-26-27
Class 0.5 (5 VA) from 48 to 1000 Hz
12.40"
(315 mm)
Maximum Conductor Size:
Cable: 2.52" Ø max. (64mm)
Bus bar: 1.97 x 5.31" (50 x 135 mm)
2.52 x 3.94" (64 x 100 mm)
Accuracy and Phase Shift*:
1000A RANGE
Primary current
Accuracy %
Phase shift
50A
3%
3°
200A
1.5%
1.5°
1000A
1%
1°
MECHANICAL SPECIFICATIONS
Operating Temp: 14° to 122°F (-10° to 50°C)
Load Impedance: 0.1Ω
Storage Temp: -13° to 176°F (-25° to 80°C)
Overload: 1200A for 10 mn
Influence of Temperature: < 0.1% per 10°K
Ampere Second Product: 15 A.s
Jaw Opening: 3.54" (90 mm)
Accuracy: Per IEC 185-26-27
GlobalTestSupply
.comfrom 48sales@GlobalTestSupply.com
Class 1 (2.5VA)
to 1000 Hz
ORDERING INFORMATION
Current Probe JM865A ...................Cat #2110.88
Includes a user manual and a product warranty
and registration card
Accessories:
Leads, set of 2, 5 ft safety (1000V) ...Cat #2111.29
Lead No. 211 for Probe 5A Series
(5 ft rated 250V)................................Cat #2950.06