Download RMS (Scanner) Module User`s Guide

Transcript
Global Function
[`SEt] Setup Page
[`LgC] Logic Menu
U
U ser
Li D ser Se
Di ne i Se tti
sp F sp tt ng
la re lay ing s R
y U qu P s
e
ni enc lai Sav sto
ts y rs e re
AC
[Fn] Function : Off, AND, OR, Equal To, NAND, NOR, Not Equal To, Latch, RS Flip
Flop
[SFn;A] Source Function A : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
[Si;A] Source Instance A : 1 to 24
[S2;A] Source Zone A : 0 to 16
[SFn;b] Source Function B : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
Global
Overview
[Si;b] Source Instance B : 1 to 24
Instances - 1 per RMS
[S2;b] Source Zone B : 0 to 16
Output Value
[SFn;C] Source Function C : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
[`SEt] Setup Page
[gLbL] Global Menu
[Si;C] Source Instance C : 1 to 24
[C_F] Display Units : F, C
[S2;C] Source Zone C : 0 to 16
[AC;Lf] AC Line Frequency : 50 Hz, 60 Hz
[SFn;d] Source Function D : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
[d;PrS] Display Pairs : 1 to 15
[USr;S] User Settings Save : None, User Set 1, User Set 2
[Si;d] Source Instance D : 1 to 24
[USr;r] User Settings Restore : None, User Set 1, User Set 2, Factory
[S2;d] Source Zone D : 0 to 16
[SFn;E] Source Function E : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
[Si;E] Source Instance E : 1 to 24
[S2;E] Source Zone E : 0 to 16
[SFn;F] Source Function F : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
Logic Function
Function
Error Handling
[Si;F] Source Instance F : 1 to 24
[S2;F] Source Zone F : 0 to 16
Source Function A
Source Instance A
Source Zone A
Source Error A
[SFn;g] Source Function G : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer,
Variable
Source Value A
Source Value B
Source Value C
[Si;g] Source Instance G : 1 to 24
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Value D
[S2;g] Source Zone G : 0 to 16
Source Value E
[SFn;h] Source Function H : None, Alarm, Compare, Counter, Digital I/O, Profile
Event Out A to H, Function Key, Limit, Logic, Special Function Out 1 to 4, Timer,
Variable
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Value G
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value F
[Si;h] Source Instance H : 1 to 24
[S2;h] Source Zone H : 0 to 16
Source Value H
[Er;h] Error Handling : True Good, True Bad, False Good, False Bad
Logic
Overview
[oPEr] Operation Page
[`LgC] Logic Menu
[Su;A] Source Value A : Off, On
Instances - 24 per RMS
[Su;b] Source Value B : Off, On
[Su;C] Source Value C : Off, On
[Su;d] Source Value D : Off, On
Source Function F
Source Instance F
Source Zone F
Source Error F
[Su;E] Source Value E : Off, On
[Su;F] Source Value F : Off, On
[Su;g] Source Value G : Off, On
[Su;h] Source Value H : Off, On
Source Function G
Source Instance G
Source Zone G
Source Error G
Source Function H
Source Instance H
Source Zone H
Source Error H
[o;u] Output Value : Off, On
An error, when read, can indicate any of the following:
None, Open, Shorted, Measurement Error, Bad Cal Data,
Ambient Error, RTD Error, Fail, Math Error, Not Sourced,
Stale
Output Value
Wat low EZ-ZONE ® RMS Module
Error
•
104
•
Chapter 6 Features