Download RMS (Scanner) Module User`s Guide
Transcript
Global Function [`SEt] Setup Page [`LgC] Logic Menu U U ser Li D ser Se Di ne i Se tti sp F sp tt ng la re lay ing s R y U qu P s e ni enc lai Sav sto ts y rs e re AC [Fn] Function : Off, AND, OR, Equal To, NAND, NOR, Not Equal To, Latch, RS Flip Flop [SFn;A] Source Function A : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable [Si;A] Source Instance A : 1 to 24 [S2;A] Source Zone A : 0 to 16 [SFn;b] Source Function B : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable Global Overview [Si;b] Source Instance B : 1 to 24 Instances - 1 per RMS [S2;b] Source Zone B : 0 to 16 Output Value [SFn;C] Source Function C : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable [`SEt] Setup Page [gLbL] Global Menu [Si;C] Source Instance C : 1 to 24 [C_F] Display Units : F, C [S2;C] Source Zone C : 0 to 16 [AC;Lf] AC Line Frequency : 50 Hz, 60 Hz [SFn;d] Source Function D : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable [d;PrS] Display Pairs : 1 to 15 [USr;S] User Settings Save : None, User Set 1, User Set 2 [Si;d] Source Instance D : 1 to 24 [USr;r] User Settings Restore : None, User Set 1, User Set 2, Factory [S2;d] Source Zone D : 0 to 16 [SFn;E] Source Function E : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable [Si;E] Source Instance E : 1 to 24 [S2;E] Source Zone E : 0 to 16 [SFn;F] Source Function F : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable Logic Function Function Error Handling [Si;F] Source Instance F : 1 to 24 [S2;F] Source Zone F : 0 to 16 Source Function A Source Instance A Source Zone A Source Error A [SFn;g] Source Function G : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Output 1 to 4, Timer, Variable Source Value A Source Value B Source Value C [Si;g] Source Instance G : 1 to 24 Source Function B Source Instance B Source Zone B Source Error B Source Value D [S2;g] Source Zone G : 0 to 16 Source Value E [SFn;h] Source Function H : None, Alarm, Compare, Counter, Digital I/O, Profile Event Out A to H, Function Key, Limit, Logic, Special Function Out 1 to 4, Timer, Variable Source Function C Source Instance C Source Zone C Source Error C Source Value G Source Function D Source Instance D Source Zone D Source Error D Source Function E Source Instance E Source Zone E Source Error E Source Value F [Si;h] Source Instance H : 1 to 24 [S2;h] Source Zone H : 0 to 16 Source Value H [Er;h] Error Handling : True Good, True Bad, False Good, False Bad Logic Overview [oPEr] Operation Page [`LgC] Logic Menu [Su;A] Source Value A : Off, On Instances - 24 per RMS [Su;b] Source Value B : Off, On [Su;C] Source Value C : Off, On [Su;d] Source Value D : Off, On Source Function F Source Instance F Source Zone F Source Error F [Su;E] Source Value E : Off, On [Su;F] Source Value F : Off, On [Su;g] Source Value G : Off, On [Su;h] Source Value H : Off, On Source Function G Source Instance G Source Zone G Source Error G Source Function H Source Instance H Source Zone H Source Error H [o;u] Output Value : Off, On An error, when read, can indicate any of the following: None, Open, Shorted, Measurement Error, Bad Cal Data, Ambient Error, RTD Error, Fail, Math Error, Not Sourced, Stale Output Value Wat low EZ-ZONE ® RMS Module Error • 104 • Chapter 6 Features