Transcript
Baudrate ASCII: SSIOUT Default: 0 valid for all OPMODES Determines the serial transmission rate. Change this only while the amplifier is disabled. ID Function 0 200 kBaud 1 1.5 MBaud SSI-Clock ASCII: SSIINV Default: 0 valid for all OPMODES Determines whether the output level is normal, or inverted. Change this only while the amplifier is disabled. ID Function 0 Normal 1 Inverted SSI-Code ASCII: SSIGRAY Default: 0 valid for all OPMODES Determines whether the output is in binary or GRAY code. Change this only while the amplifier is disabled. ROD Interpolation ID Function 0 Binary 1 Gray ASCII: ENCOUT Default: 16 valid for all OPMODES Determines the multiplier for the number of lines of the feedback encoder per electrical motor rotation. Maximum output pulse value: 400 000 pulses/second 79