Physical Interface
7.6.1.2
AW00011918000
Line Schematic
The camera is equipped with two physical input lines designated as Input Line 1 and Input Line 2.
The input lines are accessed via the 12-pin receptacle on the back of the camera.
As shown in the I/O line schematic, each input line is opto-isolated. See the previous section for
input voltages and their significances. The current draw for each input line is between 5 and 15 mA.
Figure 38 shows an example of a typical circuit you can use to input a signal into the camera.
By default, Input Line 1 is assigned to receive an external hardware trigger (ExTrig) signal that can
be used to control the start of image acquisition.
12-Pin
Receptacle
Current Limiter
In_1_Ctrl
1
I/O_In_1 2
3
I/O_In_Gnd 4
5
6
7
8
9
10
11
12
Your
Gnd
Input
Voltage
+0 to +24 VDC
Your
Gnd
Camera
Fig. 38: Typical Voltage Input Circuit
For more information about input line pin assignments and pin numbering, see Section 7.2 on
page 76.
For more information about how to use an ExTrig signal to control image acquisition, see
Section 9.4.5 on page 112, Section 9.5.3 on page 120 and Section 9.6.3 on page 131.
For more information about configuring the input lines, see Section 8.1 on page 87.