CLEANING THE OVER THE WALL (CONVECTION)
CELL
WARNING: Failure to heed the following may result in injury or death.
Disconnect all AC power when installing or servicing this system. Follow
all state, local, and National Electrical Code(s) (provincial and Canadian
Electrical Code(s) if applicable).
• To avoid damaging splashes, always add acid to water, never add water
to acid. Wear safety glasses and use other appropriate personal
protection equipment.
• The SpaPilot® must be turned off prior to cleaning. Dangerous fumes
can be generated when the cell is cleaned with acid.
•
Inspect Cell Blades
1)
2)
3)
View the titanium blades through the clear wall of the cell. (It is not
possible to remove the cell blades from the cell body.)
If there are calcium deposits on the ends or
2
between the cell blades, then clean the cell.
Do not use any mechanical means to clean the
cell. Do not scrape the blades.
2
Clean the Cell Blades
4)
5)
6)
7)
8)
9)
WARNING: Confirm that the SpaPilot® is off
before proceeding. Dangerous fumes may be
generated during cleaning with acid.
2
Fully immerse cell in a full strength solution of
white kitchen vinegar.
•
A solution of 4 parts water to 1 part muriatic
acid can also be used.
•
To prevent splash back when using acid, always put water in the
bucket first, then add the acid to the water.
The solution should bubble as it cleans the cell.
Remove Convection cell from the solution and inspect. Repeat cleaning
procedure as needed until cell blades have no calcium deposits.
Rinse the cell with clean water (not in spa).
Properly dispose of cleaning solution.
5
CAUTION: Automatic reversing is less effective on the
“Over the Wall” (Convection) cell due to the lower water flow
through the cell. Periodic manual cleaning of the “Over the
Wall” cell may be required. Locating the cell in the path of the
circulation return jet will minimize cleaning cycles.