Download Inner Range IQ Plus Programming Manual V3.604
Transcript
Ver. 3.604 (31/03/05) p75 INNER RANGE IQ. PLUS Programmer’s Manual. ADDRESS DEFAULT FUNCTION (Data Type) Operation. a) When an Autoarm Area is disarmed, the Re-Autoarm timer will be started for that Area. b) While the timer is running, any Zone Input activity detected in the Area will cause the timer to be re-started. (Thereby preventing the Area from Re-arming) c) When the Re-Autoarm timer has run for the specified time without detecting any Zone Input activity, the Area will automatically be Rearmed. To implement the Re-Autoarm feature, the following options must be programmed: 1) The Area must be programmed as an Autoarm Area. i.e. A TimeZone must be assigned to the Area in the Area Arming options. ( Address 551 [Area 1] to 554 [Area 4] ) NOTE: If you do not wish the Area to turn On at the End time specified in the TimeZone, assign a TimeZone that has the Start and End times programmed to 00:00. 2) Program a “Re-Autoarm Time” to a value of 1 to 255 Minutes to specify how long the Area can remain dis-armed without detecting any Zone Input activity. (If this period expires without any Zone Input activity being detected, the Area will automatically arm) 3) It is recommended that the Auto-Arm Pre-Warn Time (Address 907) and/or Area Exit Delay Time (Address 541 to 544) is programmed for the Area/s to provide a warning that the Area is about to automatically Arm. Settings: 0 1 to 255 909 5 Seconds There will be no Re-autoarm function. Re-Autoarm Timer Value. ENHANCED TERMINAL AUXILIARY TIME (0 TO 255 SECONDS) (RF AND ACCESS) Sets the time period that the Auxiliaries on an RF Terminal will be activated when a Wireless Remote Key activates an Auxiliary Event. 910 0 Seconds SIREN HOLD-OFF TIME (0 TO 255 SECONDS) Sets the time period that the activation of the Siren Speaker output will be delayed after an alarm event occurs. Applies to Siren Speaker O/P & Auxiliary Event Type 9. 911 60 Seconds “24 HR FIRE” ZONE (SMOKE DETECTOR) IGNORE TIME (0 TO 255 SECONDS) This timer is activated on any “Smoke Detector Reset” Auxiliary Event and sets the time period that the system will ignore alarms on Zones programmed as Zone Type 11 - “24 Hour Fire”. 912 30 Minutes WALK TEST TIME (0 TO 255 MINUTES) This timer is activated when a Walk Test is started and sets the time that the system will remain in Walk Test mode before automatically exiting. The timer will be cancelled if the Walk Test is exited by pressing the <CLR> key on the Terminal.