Download 1 - firma-web

Transcript
3.5.3
Reassembly (see Diagrams, Pages 17, 18 and 19)
3.5.3.1
Reinstallation of Pump Hose (Item 3)
− Lubricate the outside of the hose (Item 3) (see Para. 3.4.3).
− Tighten the pins (Item 53) completely in the sleeve (Item 6).
− Insert the hose (Item 3) in the sleeve (Item 6) with flat seal (Item 101).
6
101
3
3 mm
53 x 4
− Tighten the counterflange (Item 51) to the end of the threading on the insert (Item 37).
− Place the insert (Item 37) in the hose, with the smooth holes of the counterflange (Item 51)
facing the pins (Item 53), then tighten everything with the nuts (Item 52), to push the
counterflange (Item 51) against the priming plate (Item 6). When tightening, the hose (Item
3) must be held, to prevent it from sliding back into the sleeve (Item 6) (3 mm maximum
dimension).
51
3
101
6
37
52
53 x 4
− Insert the hose (Item 3) in the pump housing (Item 2) so as to position the pins (Item 53)
off-centre, and the tapped holes of the counterflange (Item 51) horizontally. This operation
is carried out with the pump running.
− Shut down the pump when the hose (Item 3) has come out the other end of the pump
housing (Item 2).
6
52 x 4
51
58
37
2
100
53 x 4
Page 26
!: (33) 01 41 08 15 15 – Internet : http:/www.pcmpompes.com
Email : pcm@pompes.com