super B Lithium batteries to perform better 4.4.4. Connecting a charger to the battery ! Warning! Ensure you have completed all the previous steps described in chapter 4 before connecting the battery to the charger. 1. Connect the charger behind the BMS switch off device as displayed in Figure 10 2. Disconnect the charger from the mains and the battery if it is not used for a long time Bi-stable Relay Load Battery terminal 13.2V DC Charger GND GND Figure 10. Connecting the charger 4.4.5. Disconnecting a battery 1. 2. 3. 4. Turn off any device or charger the battery is connected to Turn off the external BMS (latching) relay or external BMS cut-off switch Disconnect the negative wire from the - terminal of the battery Disconnect the positive wire from the + terminal of the battery 21