Download CICS-WINDOWS

Transcript
In CICS 1/7 and above, the TCTTE entries are logged to the restart dataset each time a terminal
logs on. This includes the entries containing a pseudo terminal ID, if in use. Then when an emergency restart is done, separate TCTTE entries are created for each pseudo terminal ID, which is
not correct. If autoinstall is used for TCT definitions, these pseudo entries are automatically deleted after a few seconds. While this condition does not really cause any problems with the operation of CICS, it means that excess storage is tied up for TCTTE entries that are never used.
To alleviate this problem, this batch program can be included in the CICS start-up JCL, prior to
initializing CICS. It runs very quickly, and will scan through the restart dataset (DFHRDS) deleting all pseudo terminal entries that it finds. Then when an emergency restart is done, only the real
terminal entries are created.
PERFORMING MACRO LEVEL FUNCTIONS IN CICS 3.2 AND 3.3
Despite IBM’s general instruction, macro level assembler programs can still operate in CICS 3.2,
3.3 and 4.1, with certain restriction. The following rules apply:
1)
No file control activity. The DFHFC macros and all associated control blocks have been
removed. File I/O must be performed in command level.
2)
No GETMAIN CLASS=TEMPSTRG. You must obtain USER storage for DFHTS functions.
3)
Must be in 31-bit addressing mode. Most control blocks and nucleus modules are located
above the line.
ACCESSING THE TCA AND CSA
The following instructions will locate the TCA in MVS/XA or MVS/ESA:
L
L
L
L
USING
L
USING
R13,X'021C'(R0)
R13,X'D0'(R13)
R13,X'14'(R13)
R13,8(R13)
DFHCSADS,R13
R12,CSACDTA
DFHTCADS,R12
Load TCA address
Locate the CSA
Locate the CSA
Locate the CSA
Address the CSA
Load current TCA address
Address it
[Note]: Source copybooks and macro-level macros are located in CICS321.SDFHMAC.
© Copyright 1995-2004 UNICOM Systems, Inc. All Rights Reserved. GP50-0420-2 CICS-WINDOWS V4.2.0
325