Download Timer Relay Module (FRM01) User Manual
Transcript
disconnect,and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration≥20ms),repeat the above function. [Function 4]: Timing Disconnect Then Pull-in : after power on, the relay immediately pull-in, when arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay pull-in, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration≥20ms),repeat the above function. [Function 5]: Unlimited Cycle Timing Mode A: after power on, the relay don’t pull-in, when arrived the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect, then repeat the above status, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration≥20ms),repeat the above function. [Function 6]: Unlimited Cycle Timing Mode B: after power on, the relay immediately pull-in, when arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay pull-in,then repeat the above status, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration ≥20ms),repeat the above function. [Function 7]: Limited Cycle Timing Mode A: after power on, the relay don’t pull-in, when arrived the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect, then repeat the above status "NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999,give CH1 interface a high pulse signal(high level duration≥20ms),repeat the above function. [Function 8]: Limited Cycle Timing Mode B: after power on, the relay immediately pull-in, when arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay pull-in,then repeat the above status "NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999, give CH1 interface a high pulse signal(high level duration≥20ms),repeat the above function. [Function 9]: Self-locking Mode:give CH1 interface a high pulse signal, the relay pull-in, again give a high pulse signal, the relay disconnect. [Function 10]: Trigger Mode:contain delay off function, the relay does not operate after power on ,give CH1 interface a high pulse signal, the relay pull-in immediately, when the high pulse signal disappeared, the relay still pull-in, when arrived the setting time T1 relay disconnect, the T1 can be adjustable between 0 second-270 hours. Remark: in this function, if T1 is 0 second, give CH1 connector a high pulse signal, 2