disconnect,and the T1 and T2 can be adjustable between 0.1 second -270 hours, give
CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 4]:
Timing Disconnect Then Pull-in : after power on, the relay immediately pull-in, when
arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay
pull-in, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give
CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 5]:
Unlimited Cycle Timing Mode A: after power on, the relay don’t pull-in, when arrived
the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,
then repeat the above status, and the T1 and T2 can be adjustable between 0.1 second
-270 hours, give CH1 interface a high pulse signal(high level duration≥20ms),repeat
the above function.
[Function 6]:
Unlimited Cycle Timing Mode B: after power on, the relay immediately pull-in, when
arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay
pull-in,then repeat the above status, and the T1 and T2 can be adjustable between
0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration
≥20ms),repeat the above function.
[Function 7]:
Limited Cycle Timing Mode A: after power on, the relay don’t pull-in, when arrived
the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,
then repeat the above status "NX" times, the T1 and T2 can be adjustable between
0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999,give
CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 8]:
Limited Cycle Timing Mode B: after power on, the relay immediately pull-in, when
arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay
pull-in,then repeat the above status "NX" times, the T1 and T2 can be adjustable
between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between
1-9999, give CH1 interface a high pulse signal(high level duration≥20ms),repeat
the above function.
[Function 9]:
Self-locking Mode:give CH1 interface a high pulse signal, the relay pull-in, again
give a high pulse signal, the relay disconnect.
[Function 10]:
Trigger Mode:contain delay off function, the relay does not operate after power
on ,give CH1 interface a high pulse signal, the relay pull-in immediately, when
the high pulse signal disappeared, the relay still pull-in, when arrived the setting
time T1 relay disconnect, the T1 can be adjustable between 0 second-270 hours.
Remark: in this function, if T1 is 0 second, give CH1 connector a high pulse signal,