Download Untitled - Stemmer Imaging

Transcript
MV-D640 User’s Manual
In order to use the strobe, the optocoupler must be powered with 5 .. 15 V DC. The
STROBE signal is an open-collector output, therefore, the user must connect a pull-up
resistor (see Table 10) to STROBE_VDD (5 .. 15 V DC) as shown in Figure 10. This resistor
should be located directly at the signal receiver.
Figure 10: Circuit for the Trigger/Shutter signals (USB)
Caution:
The maximum sink current of the STROBE pin is 8 mA. Do not connect
inductive or capacitive loads, such loads may result in damage of the
optocoupler!
Table 10: Pull-up resistor for the strobe output
STROBE_VDD
Pull-up Resistor
15 V
> 3.9 kOhm
10 V
> 2.7 kOhm
8V
> 2.2 kOhm
7V
> 1.8 kOhm
5V
> 1.0 kOhm
5.1.5 Status Indicator for CameraLink Models
A dual-color LED on the back of the camera gives information about the current status.
LED Green
Green when an image is output. At slow frame rates, the LED blinks with
the FVAL signal. At high frame rates the LED changes to an apparently
continuous green light, with intensity proportional to the ratio of readout
time over frame time.
LED Red
Red indicates an active serial communication with the camera.
REV: 2.0
Page 24