Download Untitled - Stemmer Imaging
Transcript
MV-D640 User’s Manual In order to use the strobe, the optocoupler must be powered with 5 .. 15 V DC. The STROBE signal is an open-collector output, therefore, the user must connect a pull-up resistor (see Table 10) to STROBE_VDD (5 .. 15 V DC) as shown in Figure 10. This resistor should be located directly at the signal receiver. Figure 10: Circuit for the Trigger/Shutter signals (USB) Caution: The maximum sink current of the STROBE pin is 8 mA. Do not connect inductive or capacitive loads, such loads may result in damage of the optocoupler! Table 10: Pull-up resistor for the strobe output STROBE_VDD Pull-up Resistor 15 V > 3.9 kOhm 10 V > 2.7 kOhm 8V > 2.2 kOhm 7V > 1.8 kOhm 5V > 1.0 kOhm 5.1.5 Status Indicator for CameraLink Models A dual-color LED on the back of the camera gives information about the current status. LED Green Green when an image is output. At slow frame rates, the LED blinks with the FVAL signal. At high frame rates the LED changes to an apparently continuous green light, with intensity proportional to the ratio of readout time over frame time. LED Red Red indicates an active serial communication with the camera. REV: 2.0 Page 24