Download User Manual

Transcript
Parameter
Name & Function
Default Unit
Setting of stopping mode after finding Home
signal.
Setting
Explanation
After detecting the Home signal, it sets this
position to be the Home reference (Un-14
encoder feed back rotating number and
Un-15 encoder feed back pulse number are
0
Pn365.3
all 0), motor decelerates and stops.
Then it reverses direction in 2nd speed to
detect the Home Position again then it
decelerates and stops..
After detecting the Home signal, it sets this
position to be the Home reference (Un-14
1
encoder feed back rotating number and
Un-15 encoder feed back pulse number are
all 0), motor decelerates and stops.
Machine Home reference search speed. 1st speed
Pn366 ( Fast)
HOME Refeence search speed . Speed 1.
Machine Home position search speed. 2nd Speed
Pn367 (Slow)
Home position search speed . Speed 2.
Home position offset . Number of revolutions.
Once the searched home position is found in
accordance with Pn365 (Home routine mode), then it
Pn368
will search by a number of revolutions and pulses set in
parameters Pn368 and Pn 369 to find the new (off set)
Home position.
Home position offset . Number of Pulses.
Pn369
Home Offset position = Pn368(Rotate Number) x
Number of Encoder Pulse per Rotation x 4
+ Pn369(Pulse Number)
6-24
0
X
100
rpm
50
rpm
0
rev
0
pulse
Setting Control
Chapter
Range Mode
0
│
1
Pi
Pe
5-4-8
Pi
Pe
5-4-8
Pi
Pe
5-4-8
-30000
│
30000
Pi
Pe
5-4-8
-32767
│
32767
Pi
Pe
5-4-8
0
│
2000
0
│
500