Transcript
MP-11x & Microsoft Exchange Server 2007 Table 3-2: Adding a BootP Client 3. 3.2.2 Use the MediaPack chassis' reset button to physically reset the gateway causing it to use BootP; the MediaPack changes its network parameters to the values provided by the BootP. Assigning an IP Address Using CLI via RS-232 You can assign an IP address to the MediaPack using CLI by establishing a serial connection between your PC and the MediaPack. ¾ To assign an IP address using CLI via RS-232, take these 5 steps: 1. Connect the MediaPack's RS-232 port (labeled RS-232), located on the rear panel, to your PC. 2. Use serial communication software (e.g., HyperTerminalTM) to connect to the MediaPack. Set your serial communication software to the following communications port settings: Baud Rate: 115,200 bps; Data bits: 8; Parity: None; Stop bits: 1; Flow control: None. 3. At the CLI prompt, type conf, and then press <Enter>; the configuration folder is accessed. 4. To check the current network parameters, at the prompt, type GCP IP, and then press <Enter>; the current network settings are displayed. 5. Change the network settings by typing the following: SCP IP [ip_address] [subnet_mask] [default_gateway] (e.g., SCP IP 10.13.77.7 255.255.0.0 10.13.0.1) Note: This command requires you to enter all three network parameters (each separated by a space). The new settings take effect on-the-fly and connectivity is active at the new IP address. To save the configuration, at the prompt, type SAR, and then press <Enter>; the MediaPack restarts with the new network settings. Fast Track Guide 16 Document #: LTRT-35201