We will have therefore to include 4 buttons in our UCP, with the following control information: Key 1: select Preset 1, value 12 Key 2: select Preset 3, value 37 Key 3: select Preset 6, value 62 Key 4: select Preset 7, value 87 In our example, each one of these buttons has to operate the virtual control #16, which is the one we selected as control for our virtual selector in the REMOTES section: When you press one of these buttons, the virtual control #16 should take the corresponding value among the 4 ones in the table above, value 12 for the first button, value 37 for the second button, and so on. To enable this function for each button, you must follow the following steps (for the previous example): Select the virtual control #16 for Param in the Properties Check the Push Only (*) checkbox Enter the corresponding value (12, 37, 62 or 87) in the Data field (*) A standard button always sends a value of 100 when pressed and 0 when released, an ideal behavior to recall a specific preset or activate a MUTE. When it's necessary to send a single specific value when pressing the button and nothing when releasing it, as it is the case with this Presets selector, the Only Push checkbox should be checked. The settings for each button could therefore be: 182