B-22 Direct ASCII Communication
TRANS 01D
Error Code
Description
!74 Error in command
execution
A procedure command set in the CLC /
TRANS 01-D or drive parameter has not been
successfully completed.
!75 Comm. port buffer
overflow
The serial port receive buffer has overflowed. In
current versions of the CLC / TRANS 01-D, this
buffer is 512 bytes. To avoid this error, the host
must communicate in half duplex or use XON-XOFF
handshaking correctly.
!76 Invalid Block
This message is reserved for the TRANS 01-D
version of the CLC / TRANS 01-D. See the
documentation for this version.
!77 Can’t save
sequencer while it is
running
Sequencer data can only be save while the program
is not running, or while no user tasks are running a
sequencer.
!78 Service channel in
use
The SERCOS service channel is being used by a
user program task or by a CLC / TRANS 01-D
internal process, and has suspended the
transmission of a list or text string. See the
description of parameter C-0-0010, bit 12.
!79 PID block number
does not exist
This error is issued when the selected PID block is
not initialized in the user program.