BLACK
LED3
DATA
TAP
AUDIO TAP
CHECK REQUIRED
BATTERY STANDBY
TIME WITH LOCAL
REGULATION.
CONTROL
PANEL
DRAWS
66mA IN
STANDBY
RED
IF BOX TAMPER
IS ENABLED IN
LOCATION 37,
CONNECT A
NORMALLY
CLOSED SWITCH
TO THESE PINS.
TO PREVENT RISK
OF ELECTRICAL
SHOCK, ALWAYS
DISCONNECT THE
TELEPHONE LINE
PRIOR TO
SERVICING.
WARNING
THIS LED IS
FOR PROPER
CIRCUIT
OPERATION
ONLY.
COM
COM
FOR PROPER CONNECTION
OF OUTDOOR BELLS/SIRENS :
SEE APPROPRIATE DIAGRAMS
ZONES
POS (Aux Pwr +)
ALL CIRCUITS ARE
CLASS 2 POWER
LIMITED, EXCEPT
BATTERY CIRCUIT.
THE TOTAL STANDBY
CURRENT DRAWN FROM
TERMINALS SMOKE+,
KEYPAD POS
(AUX PWR+) WHEN
ADDED TOGETHER,
MUST NOT EXCEED.
1A WITH A 35VA
TRANSFORMER.
CADDX
NX-4
MAX TOTAL WIRE
RUN IS 800m.
MAX NUMBER OF
DEVICES IS 8 KEYPADS
AND 1 OTHER DEVICE.
SMOKE+ TERMINAL IS CURRENT
LIMITED TO 250 mA.
KEYPAD + TERMINAL IS LIMITED
TO 1 AMP.
DO NOT
CONNECT
230 VAC TO
TERMINAL
STRIP.
230V AC
50Hz FUSE
PRIMARY
500mA
(FAST)
CE-APPROVED
TRANSFORMER
16.5 VAC, 35 VA
ALL ZONE INPUTS
ARE SUPERVISED.
(Supervised)
COM (Aux Pwr -)
DATA
AUX2
SMOKE+
COM
SIREN
AUX 1
EARTH
AC
AC
4
3
Page 75
2
-
NX-4 Installation manual
1
TRANSMISSION OF BURGLARY/FIRE ALARMS
DIRECTLY TO A POLICE/FIRE BRIGADE
EMERGENCY NUMBER IS NOT PERMITTED.
ALARMS SHOULD BE TRANSMITTED TO AN
AUTHORIZED CENTRAL STATION.
+
-
MAX 8 KEYPADS AND
1 OTHER DEVICE.
FOR VOLTAGE OUTPUT
PROGRAM LOCATION 37,
SEGMENT 2, FEATURE 1.
CURRENT LIMITED TO
2.5 AMP MAXIMUM.
BUILT IN SIREN DRIVER
FOR 15 OR 30 WATT
SPEAKERS 4,8 OR
16 OHM LOAD.
LIGHTNING PROTECTION
THE CONTROL PANEL
MUST BE EARTH GROUNDED
FOR LIGHTNING PROTECTION
TO WORK EFFECTIVELY. THE
EARTH TERMINALSHOULD
BE TIED TO A VERIFIED EARTH
GROUND
Any zone
input
any zone
input
NX-4 WIRING DIAGRAM
Date 13/03/04