Assembly/Installation
Connection of a KaVo spindle
A KaVo spindle is connected according to the following table; on operation for the first time, check the direction
of rotation specified on the spindle (arrow).
Compliance with EMC guidelines is ensured only with the use of spindle types EMC 4060 – 4063 with shielded
connecting cable.
Signal
Inverter connection
X2.1 (U)
X2.2 (V)
X2.3 (W)
Shielded cable
Type EMV 4060 – 4063
Connection colour
1 – blue
3 –yellow
4 – black
Unshielded cable
Type 4060 – 4063
Connection colour
1 – blue
3 – violet
5 – black
Phase U
Phase V
Phase W
PTC (cold
conductor)
PTC (cold
conductor)
Protective
conductor
Shield
---
X7.1
B – brown
4 – brown
X7.6
C – white/natural
2 – white
X3 (PE)
Pull-relief terminal
Not connected
2 – yellow/green
Housing - braided
A – green
7 – yellow/green
not present
6 – natural
FB-REL1
FB-OUT-FREQ
2
1
25
24
23
22
21
20
19
18
17
16
15
14
FB-IN1
FB-REL2
3
FB-IN2
FB-REL3
4
FB-IN3
FB-REL4-OE
5
FB-IN4
FB-REL4-S
6
FB-IN5
FB-C-REL
7
FB-IN6
FB-AGND
8
FB-AIN1
FB+24V
9
FB-AIN2
FB-GND
10
FB-C-IN
FB+10V
11
FB-AOUT1
TXD-F
12
FB-AOUT2
13
RXD-F
+7V-F
X4: Remote control connection
Plug type: 25-pole D-Sub jack
Note: All connections of the 25-pole jack X4 are potentially isolated from the control and with respect to the
conductive earth up to max. 60 V DC or 25V AC.