Download F159 - Omron
Transcript
6.WEIGHING MODE SETTING AND OPERATION 6-1. Feed Weighing and Discharge Weighing 6-1-1. Feed Weighing This method controls weight of the metering tank (e.g. hopper) as it is being filled with raw material. Example of Feed Weighing In this example the metering tank is fed with raw material from the raw material tank. At first, the feeding valves are to be fully opened to feed, and closed in the order of large → medium, and medium → small at the time of Final-SP1, and Final-SP2, respectively. The feeding valves are to be completely closed at the time of Final-FF CPS.. The weighed raw materials are to be discharged to a container by opening the Discharge valves. Raw material tank Feeding valves (SP1, SP2, SP3) Metering tank Summing box Load cell Discharge valve F159 Container Belt conveyer 60