Download Bio Integrator User Guide - Bio
Transcript
Bio Integrator Plus User Guide Note: Be sure to set the selector on your amplifier to the proper input selection, e.g., if you have plugged your audio cables into "CD IN" on your amplifier, be sure to set the front control on your amplifier to "CD." Connecting the Encoder and Sensors Note: Bio Integrator Plus sensors and the encoder and interface units carry parts that may be damaged by static electric discharges. Exercise care when handling this equipment in static-prone environments. Bio Integrator Plus hardware is not warranted against damage caused by static discharge. Use anti-static mats and/or anti-static spray in areas of use and condition dry air using humidifiers. To set up the encoder unit for use: The Bio Integrator Plus expects to be connected to COM Port 2, and that this port will be committed exclusively to handling the incoming data stream from the encoder unit. (For laptop version, plug in special Y-splitter cable to COM Port 1, and follow instructions that came with the cable itself.) Plug the Pro-SB interface into COM Port 2. (For laptop version, plug Pro-SB into Y-splitter cable.) Insert one end of the optical cable into the black connector on the rear face of the Pro-SB interface unit. The end of the cable should go in about 3/4 inch. Warning: Winding or bending the fiber-optic cable in a loop smaller than 4 inches (10 cm) or bending it sharply may destroy the cable! Lightly screw down the black connector until it is firmly connected but not overtightened (do not use pliers). Insert the other end of optical cable into the white encoder connector marked "output" on the front of the encoder unit. The end of the cable should go in about 3/4 inch. Ensure that both ends of the optical cable are inserted all the way into the connectors and that the connectors are screwed firmly down. Plug the sensors you wish to use into the input jacks on the front of the encoder unit. EEG sensors must go in input jacks A and B. Later, you will configure the EEG and body measures in the Initialization Choices menu in your Bio Integrator Plus software. The default settings are channel A - left EEG; channel B - right EEG; channel C - left TEMP; channel D - right TEMP; channel E - EMG1; channel F - EMG2; channel G - SCL; channel H - PPG. Load the four enclosed AA 1.5 V rechargeable nickel-cadmium (nicad) batteries (or alkaline batteries) into the encoder unit's battery pack; check battery orientations against the diagram on the underside of the battery pack. Turn the encoder unit's power switch on. Check that the indicator light on the front of the encoder unit is on; if it is not, turn Page 20