Bio Integrator Plus User Guide
The Bio Integrator Plus includes a useful set of features that help you deal with artifacts
associated with vertical eye movements (eyeblinks) and muscle contractions. The two
options are Artifact and Artifact Clipping Level.
To help screen out high amplitude artifacts from eyeblinks or muscle tension, the Bio
Integrator Plus has a software-selectable frequency range and amplitude threshold. The
frequency range should be set for the frequency area that most interests you. The
amplitude setting should be set at a microvolt level that is just above the normal level you
would expect from a given individual.
The Artifact settings were designed primarily to reduce artifacts resulting from vertical
eyeblinks. Vertical eyeblinks are most noticeable when EEG sensors are placed on O1 or
O2, with the reference towards the front of the head. This hookup is common for protocols
calling for reducing beta and enhancing alpha/theta. However, many individuals will
exhibit substantial vertical eyeblink artifact on the crown of the head, and you may wish to
apply artifact clipping.
Setting the low-high frequency levels in Artifact determines the frequency range in which
you would like to have artifact removed. How much you remove from your signal is
determined by Artifact Clipping Level.
Choices in the Artifact Clipping Level pop-up box are in microvolts. Your choices
determine how the data are shown and recorded. The higher the setting, the greater the
risk of artifacts entering the data stream. Since eyeblinks occur mainly in delta, theta and
low alpha, it pays to examine the oscilloscopic trace and amplitude spectral display
simultaneously in a two-per-screen display. The default setting is 20 microvolts.
See Chapter 4, EEG Linegraph and Audio Feedback Bandwidth Settings, Oscilloscope,
for an exercise in artifact clipping.
Note: Artifact clipping influences all audio and visual displays and recorded data. While
Artifact and
Artifact Clipping Level were designed to remove frequencies associated with verticaleyeblinks from
the EEG data, there is no reason you cannot use them for removing excessive amplitude in the beta
bandwidth, which may be due toEMG artifact.
Tip: The Bio Integrator Plus features a built-in digital oscilloscope. You choose it just as you would
choose any other graph. The oscilloscope may be used in any of the graph size choices, e.g.,
full screen,
two per screen, or four per screen. It was included in part to help you distinguish artifacts from real
brain waves. If you are not using O1 or O2 as sensor locations, e.g., C3, C4, CZ, etc., you may want
to set artifact clipping atOff. Artifacts such as eyeblinks may be difficult to see on the oscilloscope when
sensors are placed at the crown of the head; therefore, attempting to clip them out of the EEG signal
through artifact clipping may be problematic. To see if vertical eye movementseyeblinks)
(
are present at
the crown of the head, put the oscilloscope on afull screen or two per screen display, and have the
client blink or flutter the eyelids. If the artifact from the
eyeblinks shows up clearly on the oscilloscope,