Download DigiCall: Communications system. User Manual

Transcript
DigiCall™ System Installation and Operation
3-3
Figure 3-1
Installation
Four and Eight Station Master Intercom Board Setup
NOTE: The pictures shown will alternate
from Four Station to Eight Station Master
boards. They are the same except for
component population. Complete all setup
steps, wiring connections, and
modifications before applying power to
the DigiCall™ system.
1.
2.
3.
Remove the four screws that secure the
Master Intercom cover. Set the screws and
cover aside.
Set the <UNUSED PORT/TELCO>
switch to the <TELCO> position.
Figure 3-1A
The three switches shown in Figure 3-1B
are used to select the activation tones used
when answering or ending remote calls.
Set the switches as follows: top right to
<1>, bottom right <*> to <ON>, bottom
left <#> to <OFF>.
NOTE: Steps 4 and 5 apply to facilities
while they operate in local mode.
4.
5.
6.
Set the number of telephone rings (2, 4, 6,
8) by installing the jumper wire located
below the <RING COUNT> terminals, to
the desired <RING COUNT> terminal.
Figure 3-1C
The <LONG/SHORT> ring jumper
controls the type of ring; short or long, that
announces an intercom call. Set the
jumper to <LONG>. Many portable
phones will not recognize the short ring.
Figure 3-1D
The <DB/NDB> jumpers are set
according to the type of substation used.
Set the <NDB> position for all DigiCall™
substations. Set the <DB> position for
DigiGate keypads.
Figure 3-1E
NOTE: For DigiCall™ substations
(P/N 9001-051, 9001-053, 9001-061, or
9001-063), set the <DOOR BELL/NO
DOOR BELL> jumpers across the
<NDB> contacts. Figure 3-1E