Download Vansco User Guide

Transcript
Inputs
5.2.1. VMM1615 DC-Coupled Frequency Input Capabilities
A DC-coupled frequency input allows you to read the frequency of external
signals that switch between system ground, and sensor or battery power. This
input is ideal for use with hall-effect type sensors.
The following table provides specifications for the VMM1615's DC-coupled
frequency input:
DC-Coupled Frequency Input Specifications
Item
MIN
NOM
MAX
0
-
32
V
5.31
5.36
5.41
kΩ
Capacitance at pin
-
.005
Overvoltage
-
-
36
V
Frequency accuracy
-
-
5
%
Frequency range
1
-
10000
Hz
Negative going threshold
-
-
1.56
V
Positive going threshold
3.82
-
-
V
Input voltage range
Pull-up/pull-down resistance
UNIT
µF
5.2.2. VMM1615 DC-Coupled Frequency Input
Configuration
The DC-coupled frequency input can be configured to use a pull-up resistor, pulldown resistor or neither.
The following diagram shows the configuration for the DC-coupled frequency
input:
Internal to
product
Application
sensor
Filter
+
-
Pull-up/down option
Figure 11: DC-coupled frequency input configuration
28
VMM1615