Introduction Each chapter in this document discusses each of these integration modes in detail. 1.1.3 Handling eG Alarms in a Trouble Ticketing System A trouble ticket system must be configured to process alarms reported to it by an eG manager. The alarm ID must be used to uniquely identify an alarm. The functions that the TT system must perform are: Determine if an alarm ID indicates a new alarm. If yes, open a new trouble ticket. If an alarm ID indicates an existing alarm, check the priority of the alarm. If the priority is Normal, this implies that the alarm has been closed in eG Enterprise. Hence, close the corresponding trouble ticket in the TT system. If an alarm ID indicates an existing alarm and the priority of the alarm is not Normal, update the corresponding trouble ticket with the current priority of the alarm and with its current description. These functions often involve scripting/configurations on the TT system. Once the above steps are accomplished, by reviewing the status of the trouble tickets, administrators can be immediately aware of the current status of the infrastructure being monitored, without having to login to the eG Enterprise console. 3