Download English - Siqura
Transcript
HSD62x 11.10.4 Measurements configuration Video > Image Monitor > VCA Settings The default Measurements values will mostly work well for you. If you do need to modify them you can do so in the VCA Settings section. Item Description Configure Alarms Min. event duration Alarm output delay time: the time span that is to elapse before a continued change in conditions actually activates/deactivates the alarm output. Alarm output True or False. Indication of current status. Configure Focus Measurement Allow you to enable/disable each measurement separately and customise its alarm threshold and hysteresis to your requirements. Configure Exposure Measurement Configure Contrast Measurement Configure SNR Measurement Configure Evaluation Rate The value entered here determines the speed at which the host machine processes the algorithms underlying the measurements. Higher values take up more CPU power. Auto Configure Adjusts the alarm thresholds, based upon the current measurements. The green area is centred around the current pointer position. Reset to Default Restores the original thresholds. Does not affect the current activity status of the measurements (i.e. being Enabled or Disabled). Tip: A PTZ camera moving from one preset to the next may trigger an alarm if the scene change takes too long. Setting an appropriate time for the Min. event duration parameter can delay the alarm output until the camera has adopted the new position and the alarm condition has ceased. Page 92