4. Mount (2) black 2x8 pine boards securely to the wall according to the
following diagram. The top board is used to mount the vest holding rack and
the bottom board is used to mount the holster electronics.
5. After all holsters have been connected to each other, and then to the power
supply, you still have to make a connection to the RS485 port on the scanner.
This can be from the end of one of the holster daisy chains, or it can also be
from an unused connection on the holster power supply.
6. To test the holsters, click on the “Test Holster” button on the maze devices
menu. The red LED on the holster circuit board should go on and then off
every few seconds. If not, then there is most likely a bad telephone wire. In
order to locate the bad wire, remove half of the holsters at a time until the
problem is found. Make sure that you unplug the holster power supply before
you connect or disconnect any telephone wire from any holster. You may get
lucky and not damage a holster if you unplug it with the power applied, but it
was not designed to be “hot swapped”. Please turn off the power every time
you connect or disconnect a holster telephone cord.
7. You can verify the ID#’s are all unique by clicking on the “Query Devices”
button on the Maze Devices Screen. Each LED status beacon should show a
different pattern of red LED’s. Each beacon has 8 red LED’s, and they will
show the values of the each of the DIP switches.
21