Download iLEARN System Manual

Transcript
iLEARN System Manual
SPECIAL NOTES:
ing and the doors are not closing, the following special conditions apply:
Reactivate Hall Push Buttons [J11:1 - J9:5] The Hall Push Buttons must be active during
the transition. This circuit must be reopened when either Phase 1 Operation is resumed or
Phase 2 Operation is reactivated.
turned from OFF to either HOLD or ON during the transition from Phase 2 to Phase 1 Operation while the doors are closing, the closing cycle must be interrupted and the door and
car gate reopened. The re-open sequence is accomplished by opening the normally closed
HOLD circuit between J11:1 and J8:5 to break the closing cycle and establish the reopen
cycle. The normally closed HOLD circuit may be reestablished when the door and gate
er’s Emergency Operation Phase 2 circuit (J11:1 - J8:4) should remain closed until Phase 1
Operation is resumed following the transition.
PLEASE NOTE!
Operation and transition are not intended to be inclusive. Please refer to ASME A17.1 Rule 211.3
(2000) or Rule 2.27.3 (2002 and later) for a complete description of the performance requirements.
17
ver.072012-2.08