iCAT event settings
You can also specify event-related properties on an iCAT definition:
1.
2.
3.
You can also choose a specific Icon and Sound for the event when it is shown in the event task
bar.
You can also define a special event priority for events generated by the trigger by setting the
value Priority of generated event. Please note that the event priority is a relative priority
whereby 100 is the default priority (see also 9 Handling events on page 69).
The check boxes Save event in event list and Do not save event in event list allow you to
selectively override the general setting for the camera schedule which is defined in 14.3.9
Scheduling iCAT operation and recording on page 120).
14.3.3 Defining an event trigger for object starting and stopping
In addition to object counting, iCAT also offers to detect stopping and starting objects in a defined
field.
Here are the steps for creating an event trigger for object starting and stopping:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Choose Video analysis (iCAT) from the System administration menu. This opens the Video
analysis (iCAT) dialog.
Select a camera and make sure that you have a suitable object tracking region defined that
allows for object counting (see 14.3.1 Defining an object tracking region on page 108).
In the menu select Add new definition.
In the Type pop-up menu choose Event trigger, which will expose the configuration settings.
Under the camera preview choose the Rectangle or Polygon check box.
Now you can draw the field with the mouse in the preview pane. For a polygon you just click with
the mouse to define the corners of the polygon. You close the polygon by crossing an existing
edge or by double clicking with the mouse.
Now select on what object behavior you want to trigger an event: When an Object is crossing
field, when an Object starts moving in field, or when an Object stops in field. You can also
define when an event is triggered by either selecting Object center point, Any point of object,
or Whole object.
In the field Min. time for stopping/staying inside (sec) you can enter a minimum time required
for an object that either stops or stays inside a field before an event is triggered.
When you push the Next button you can define additional constraints for the event trigger. You
can limit the counting only to certain object sizes, certain aspect ratios, and a certain speed.
Currently those measures are definable in pixels (please keep in mind that the resolution iCAT
works on is either CIF or QVGA depending on the aspect ratio of the camera). Zero values in
these fields mean that there is no constraint.
Hint for constraining the object size or speed: The size is the area of the object in pixels and
the speed is also measured in pixels per second. To know what object sizes or speeds you want
to filter it is helpful to watch a few objects passing the triggers and switch on the object markers.
These markers show the size and speed of the object in pixels. These are exactly the same
measures that you can use for the trigger. Here is an example of an object marker (Object ID is
[10], object size is 9110 pixels, speed is 208 pixels/sec):
113