Download 1. INTRODUCTION 1.1 PROBLEM DEFINITION The basic

Transcript
Embedded Network Client & Data Acquisition System
3. 3 IMPLEMENTATION ASPECTS
The initial aim of the project was to build an embedded data acquisition system that would terminate on LAN using Ethernet LAN controller CS 8900A. The major problems faced using the CS 8900A were that the chip is not readily available and is expensive. Though this being our primary goal, the system our client (DRDO) needed was just a mechanism for remote data retrieval and monitoring. So to meet the basic requirements we went on to implement the system using dial­up modem and the EPBAX system that currently exists in the client’s premises.
Another challenge put forward by our client is to make the system generic enough so as to interface with any sensor. The answer to this has been explained in the hardware design. Another trivial looking major modification was to make calibration of the sensor data flexible and changeable by the user as and when attached sensors changes. This is achieved by providing an extensive user interface.
Dial­up connection imposes its own drawbacks like: one line has to be dedicated, and the line has to be up, or has to be up whenever required. These conditions may not be met every time and hence some other means had to be there to access the data during emergency. To address these issues a major revamping of the project was done and GSM module implementation, interfacing and its driver along with the specific protocols for the hardware were incorporated in to the project. © Copyright 2004 Defense Research & Development Organization (DRDO), India
41