Download User manual
Transcript
DI-16LV-uso-e 3-02-2009 10:43 Pagina 3 Module Identity Registers Output Registers 121 122 123 124 125 126 127 Name ManuCode ProdCode-1 ProdCode-2 RelCode-1 RelCode-2 SpecialCode ProdCode-3 MODBUS Map summary (with default values) Access R R R R R R R Notes Manufacturer Code Product Code # 1 Product Code # 2 Hardware Release Code Software Release Code Special Product Code Product Code # 3 Access R/W R/W … R/W Notes User Defined Register # 1 (retentive) User Defined Register # 2 (retentive) ... User Defined Register # 10 (retentive) User defined Registers Output Registers 189 190 … 198 Name Usr#1 Usr#2 … Usr#10 Module parameters Standard Inputs Digital Inputs 1 … 16 Name DI-1 … DI-16 Access Notes R R Image of every physical input state R Latched Inputs Digital Outputs Name 101 Latched DI-1 … … 116 Latched DI-16 Access R/W R/W R/W Notes Reading: Image of physical Inputs, staticised on the leading edge 0-1 (latch) Writing: Writing “0” resets the single latch Local Values Output Registers Name Access Notes While in Loopback state the 0...15 bits of this 301 LocalV R/W register are transferred to 1..16 digital inputs. bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Channel 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Modbus address 0 … 15 100 … 115 396 397 Module digital I/O 1 ... 16 101 ... 116 397 398 Name Access Description DI-1 … DI-16 Latched DI-1 … Latched DI-16 Parity EvenOdd R R R R/W R/W R/W R/W R/W Modbus address 120 121 122 123 124 125 126 188 189 ... 197 300 397 398 399 800 801 Module registers 121 122 123 124 125 126 127 189 190 … 198 301 398 399 400 801 802 Name Access Description ManuCode ProdCode-1 ProdCode-2 RelCode-1 RelCode-2 SpecialCode ProdCode-3 Usr#1 Usr#2 Usr#n Usr#10 LocalV Ch_LO ModuleCom StackCom NodeA BaudR R R R R R R R R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W Manufacturer Code Product Code # 1 Product Code # 2 Hardware Release Code Software Release Code Special Product Code Product Code # 3 User Defined Register # 1 User Defined Register # 2 User Defined Register # n User Defined Register # 10 Local values 1...16 Channel Number 16-1 selection Module Command Register Modbus Stack Command Register Node Address Register Baud Rate Register default (hex) 0258 3136 4C56 4449 FFFF FFFF FFFF FFFF 0000 0000 0000 0000 00F7 0004 A WARNING Parameter Store/Restore This module allows parameters to be saved in a non volatile memory. In order to avoid storing configuration data parameters (registers 801...1000) by mistake, storage is only executed when a specific signature is written to the appropriate register. The signature is “ST”. Similarly, the default values of parameters are restored. On receipt of the correct signature in the appropriate register, the device restores the default parameters. The signature is “RS”. The new configuration becomes active after a reset, i.e. after a “Power Down” or a reset command (signature “RT”). See Register 400. es.Node address change by serial communications: 1. Write the new address in register 801 (NodeA). - Write value. 2. Write 0x5354 (ASCII code “ST”) to register 400. - Store value. 3. Write 0x5254 (ASCII code “RT”) to register 400. - Cold reset. Input 1 Input n Input 16 Latched Input 1 Latched Input n Latched Input 16 0: Parity Disabled; 1: Parity Enabled 0: Parity Even; 1: Parity Odd default (hex) 0 0 0 0 0 0 0 0 The data written at retentive and configuration registers are stored in EEPROM (see “Address Map organisation” paragraph for details). This type of memory has a limited number of writing cycles. Also if this number is very high (about 100000 cycles), this limit can be easily reached if the storing process is forced through a serial communications line. Please check that the storing procedure of these registers is not performed automatically. The retentive device management data (registers 401... 800) are immediately valid after writing. To maintain the values after a power OFF/ON cyle, the command Store (“ST”) must be executed. Reference documents Three way isolation diagram Serial bus Logic Input channels 1 - 16 Power supply 2500Vp 800Vp The user should refer to the following list of documents: [1] MODBUS.ORG: MODBUS Application Protocol Specification V1.1a, June 2004 Accessories, Spare Parts and Warranty Power Supply 45W 24Vdc 2A Power Supply 120W 24Vdc 5A Additional Terminal Block 2x11 Female Plug 11 Screw clamp Female Plug 11 Spring clamp RJ45 terminated cable 14cm RJ45 terminated cable 22cm Termination Adapter AP-S2/AL-DR45-24 AP-S2/AL-DR120-24 AP-S2/TB-211-1 AP-S2/SPINA-V11 AP-S2/SPINA-M11 AP-S2/LOCAL-BUS76 AP-S2/LOCAL-BUS152 AP-S2/TERM-CAN Warranty: 3 years excluding defects due to improper use