Download User manual

Transcript
DI-16LV-uso-e
3-02-2009
10:43
Pagina 3
Module Identity Registers
Output Registers
121
122
123
124
125
126
127
Name
ManuCode
ProdCode-1
ProdCode-2
RelCode-1
RelCode-2
SpecialCode
ProdCode-3
MODBUS Map summary (with default values)
Access
R
R
R
R
R
R
R
Notes
Manufacturer Code
Product Code # 1
Product Code # 2
Hardware Release Code
Software Release Code
Special Product Code
Product Code # 3
Access
R/W
R/W
…
R/W
Notes
User Defined Register # 1 (retentive)
User Defined Register # 2 (retentive)
...
User Defined Register # 10 (retentive)
User defined Registers
Output Registers
189
190
…
198
Name
Usr#1
Usr#2
…
Usr#10
Module parameters
Standard Inputs
Digital Inputs
1
…
16
Name
DI-1
…
DI-16
Access Notes
R
R
Image of every physical input state
R
Latched Inputs
Digital Outputs Name
101
Latched DI-1
…
…
116
Latched DI-16
Access
R/W
R/W
R/W
Notes
Reading: Image of physical Inputs,
staticised on the leading edge 0-1 (latch)
Writing: Writing “0” resets the single latch
Local Values
Output Registers Name
Access Notes
While in Loopback state the 0...15 bits of this
301
LocalV R/W register are transferred to 1..16 digital
inputs.
bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Channel 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Modbus
address
0
…
15
100
…
115
396
397
Module
digital I/O
1
...
16
101
...
116
397
398
Name
Access Description
DI-1
…
DI-16
Latched DI-1
…
Latched DI-16
Parity
EvenOdd
R
R
R
R/W
R/W
R/W
R/W
R/W
Modbus
address
120
121
122
123
124
125
126
188
189
...
197
300
397
398
399
800
801
Module
registers
121
122
123
124
125
126
127
189
190
…
198
301
398
399
400
801
802
Name
Access Description
ManuCode
ProdCode-1
ProdCode-2
RelCode-1
RelCode-2
SpecialCode
ProdCode-3
Usr#1
Usr#2
Usr#n
Usr#10
LocalV
Ch_LO
ModuleCom
StackCom
NodeA
BaudR
R
R
R
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Manufacturer Code
Product Code # 1
Product Code # 2
Hardware Release Code
Software Release Code
Special Product Code
Product Code # 3
User Defined Register # 1
User Defined Register # 2
User Defined Register # n
User Defined Register # 10
Local values 1...16
Channel Number 16-1 selection
Module Command Register
Modbus Stack Command Register
Node Address Register
Baud Rate Register
default
(hex)
0258
3136
4C56
4449
FFFF
FFFF
FFFF
FFFF
0000
0000
0000
0000
00F7
0004
A WARNING
Parameter Store/Restore
This module allows parameters to be saved in a non volatile memory. In order
to avoid storing configuration data parameters (registers 801...1000) by mistake, storage is only executed when a specific signature is written to the appropriate register. The signature is “ST”.
Similarly, the default values of parameters are restored. On receipt of the correct
signature in the appropriate register, the device restores the default parameters.
The signature is “RS”.
The new configuration becomes active after a reset, i.e. after a “Power Down”
or a reset command (signature “RT”). See Register 400.
es.Node address change by serial communications:
1. Write the new address in register 801 (NodeA). - Write value.
2. Write 0x5354 (ASCII code “ST”) to register 400. - Store value.
3. Write 0x5254 (ASCII code “RT”) to register 400. - Cold reset.
Input 1
Input n
Input 16
Latched Input 1
Latched Input n
Latched Input 16
0: Parity Disabled; 1: Parity Enabled
0: Parity Even; 1: Parity Odd
default
(hex)
0
0
0
0
0
0
0
0
The data written at retentive and configuration registers are stored in EEPROM (see “Address
Map organisation” paragraph for details). This type of memory has a limited number of writing
cycles. Also if this number is very high (about 100000 cycles), this limit can be easily reached
if the storing process is forced through a serial communications line. Please check that the
storing procedure of these registers is not performed automatically.
The retentive device management data (registers 401... 800) are immediately
valid after writing. To maintain the values after a power OFF/ON cyle, the
command Store (“ST”) must be executed.
Reference documents
Three way isolation diagram
Serial
bus
Logic
Input
channels
1 - 16
Power supply
2500Vp
800Vp
The user should refer to the following list of documents:
[1] MODBUS.ORG: MODBUS Application Protocol Specification V1.1a, June 2004
Accessories, Spare Parts and Warranty
Power Supply 45W 24Vdc 2A
Power Supply 120W 24Vdc 5A
Additional Terminal Block 2x11
Female Plug 11 Screw clamp
Female Plug 11 Spring clamp
RJ45 terminated cable 14cm
RJ45 terminated cable 22cm
Termination Adapter
AP-S2/AL-DR45-24
AP-S2/AL-DR120-24
AP-S2/TB-211-1
AP-S2/SPINA-V11
AP-S2/SPINA-M11
AP-S2/LOCAL-BUS76
AP-S2/LOCAL-BUS152
AP-S2/TERM-CAN
Warranty: 3 years excluding defects due to improper use