Download Reconstruct User Manual

Transcript
Chapter 9: Calibration and Measurement
Figure 9.4. Two methods are available for computing the z-distance of section n. One
computed the distance to the middle of the section: z = t1+t2+t3+...+tn-1+tn/2. The other
method computes the distance to the top of the section: z = t1+t2+t3+...+tn-1+tn.
Two methods are provided for the computation of z-distances (Fig. 9.4). One computes
the distance to the middle of the section, while the other computes the distance to the top
of the section. The former method gives more accurate z-distances and 3D
representations when sections are not uniform in thickness. Setting z-distances to the
tops of sections provides an easy way to represent gaps of missing sections by giving a
larger thickness to the sections at the top of the gaps. When section thickness is uniform,
the only difference between the methods is a half thickness offset in z values. The
method of z-distances calculation can be selected in the General Tab of the Series
Options.
Physical gaps in the series can be represented by empty sections of an appropriate
thickness. For example, suppose a series was cut at 50nm section thickness but only
every fifth section was imported. The sections were numbered 1, 6, 11, 16,... to reflect
that every fifth section was used. Assuming uniform section thickness, these sections
could all be given a thickness of 50nm. New sections could be created at 2, 7, 12,... with
thickness 200nm to represent the gaps. To get accurate object measurements with this
method, traces would need to be created in the gap sections so that the missing
thickness is accounted for in the surface area and volume calculations (see below).
Alternatively, only sections 1, 6, 11, 16,... could be created but with thicknesses 50nm,
250nm, 250nm, 250nm,..., reflecting the gaps between these sections. The z-distances to
the tops of these sections would then be 50nm, 300nm, 550nm, 800nm, etc. No
additional gap traces would be needed in this case to get accurate surface areas and
volumes.
Reconstruct v1.1.0.0
101