Download Page

Transcript
- Page 69 of 110 -
Report No. 130229
IEC 60335-2-15
Clause
Requirement + Test
10.1
TABLE: Power input deviation
Input deviation of/at:
P
P measured
(W)
dP
Required dP
Remark
1400
1408
+0,6%
-10% ~ +5%
P
TABLE: Current deviation
Current deviation of/at:
11.8
Verdict
P rated (W)
230V
10.2
Result - Remark
I rated (A)
N/A
Required dI
Remark
TABLE: Heating test, thermocouples (separately test at brewing and grinding
function)
P
Test voltage (V) .........................................:(1753W)
255,0V
⎯
Ambient (°C).............................................................:
25 °C
⎯
Thermocouple locations
I measured (A)
dI
dT (K)
Max. dT (K)
Supply cord
10
50
Internal wire connected to heating element
70
175(T200)
Internal wire between PCB
7
55(T80)
Internal wiring within coffee mill
17
80(T105)
X2 capacitor
20
75(T100)
Y2 capacitor (within coffee mill)
18
100(T125)
Interlock switch within coffee mill
15
30(T55)
PCB
32
120
Function changeover switch
32
For clause 30.1
Handle
25
50
Wood support
6
65
Plastic enclosure
40
For clause 30.1
Sleeving
75
175(T200)
Ambient of thermostat
72
195(T220)
TRF No. IEC60335_2_15E