Download user manual
Transcript
PRELIMINARY XTR-7020A-8 --------------------------------------------------------------------------------------------------------------------------------------------------- Owner’s Manual Absolute limits Operating temperature Storage temperature Power supply Input voltage Output voltage -20 °C ÷ +70 °C -40 °C ÷ +100 °C +6V -1.0 ÷ Vcc + 0.3V -1.0 ÷ Vcc + 0.3V Technical features DC Levels Supply voltage Power consumption (rx mode) Power consumption (tx mode @ -8 dBm) Power consumption (tx mode @ 10 dBm) Power consumption (stand-by mode) Logic level “1” in input/output Logic level “0” in input/output RF Band Modulation type RX Sensibility (@115200 bps) TX Power Performance Serial Bit Rate 1 Outdoor range Number of channels Channel Spacing Commutation times PWRDN → RX TX → RX RX → TX Default setting Channel Output Power (tx) 1 Min. Typ. Max. Unit 2.7 3.3 26 20 31 18 3.6 V mA mA mA µA V V 0.7xVcc 0 20 Vcc 0.3xVcc MHz 868÷870 FSK -100 -8 10 dBm dBm 9600, 19200, 38400, 57600, 115200 300 7 153.6 kHz <5 <5 <5 ms ms ms 868.19 MHz dBm 10 bps m As input serial signal is intended 8,n,1. Technical specifications may be changed without notice. AUR°EL S.p.A. declines all responsabilities deriving from a wrong utilisation of the equipment. --------------------------------------------------------------------------------------------------------------------------------------------------------------------AUR°EL S.p.A. Via Foro dei Tigli, 4 - 47015 Modigliana (FC) – ITALY 13/06/2008 Pag 2 of 13 Tel.: +39.0546.941124 Fax: +39.0546.941660 http://www.aurelwireless.com - email: rfcomm@aurel.it