Download ATLAS User`s Manual
Transcript
IMPACT Statement SELB selects the impact ionization model described by Selberherr [2]. N.CONCANNON, P,CONCANNON set the Concannon substrate current model. TOYABE is a synonym for SELB. Note: If no model selection flag is set, the model parameters from Grant [29] are used. See Chapter 3: “Physics”, “Grant’s Impact Ionization Model” Section on page 3-75. Electric Field Model Selection Flags The default electric field to use for ionization rate calculations is calculated as the modulus of the electric field over a triangle. In ATLAS3D, this is combined with the z-component of the field at each corner of the prism to give an overall field modulus at each node. This corresponds to Equation 3-260 in Chapter 3: “Physics” for a triangle. E.DIR specifies that the impact ionization rate will be calculated as a function of the electric field in the direction of the current (see Equation 3-259 in Chapter 3: “Physics”). Its alias is NEW. E.SIDE specifies that the impact ionization rate will be calculated as a function of the electric field along the side of the triangle (see Equation 3-258 in Chapter 3: “Physics”). This model is only supported in ATLAS2D. Its alias is OLD. E.VECTOR specifies that the vector electric field will be used in the calculated of the impact ionization rate (see Equation 3-257 in Chapter 3: “Physics”). OLD is the model that corresponds to Equation 3-261 in Chapter 3: “Physics” and is only supported in ATLAS2D. NEW is the model that corresponds to Equation 3-262 in Chapter 3: “Physics”, where the component of the field in the direction of the current is used in the ionisation rate calculation. It is implemented in both ATLAS2D and ATLAS3D. If the dot product of E and J is negative, then the field component is taken as 0. Consequently, impact ionisation may only occur when a current is dominated by the drift term. Model Localization Parameters DEVICE specifies the device in MIXEDMODE simulation to which the statement should apply. MATERIAL specifies what material from Appendix B: “Material Systems”, Table B-1 the statement should apply. If a material is specified then all regions defined as being composed of that material will be affected. NAME specifies what region that the IMPACT statement should apply. Note that the name must match the name specified in the NAME parameter of the REGION statement. REGION specifies that index of the region to which the impact parameters apply. Valdinoci Model Parameters VAL.AN0 specifies the value of a temperature dependent impact ionization parameter in Chapter 3: “Physics”, Equation 3-270. VAL.AN1 specifies the value of a temperature dependent impact ionization parameter in Chapter 3: “Physics”, Equation 3-270. VAL.AN2 specifies the value of a temperature dependent impact ionization parameter in Chapter 3: “Physics”, Equation 3-270. VAL.BN0 specifies the value of a temperature dependent impact ionization parameter in Chapter 3: “Physics”, Equation 3-270. SILVACO International 18-59
Related documents
ATLAS User`s Manual - UH Petroleum Engineering
Table of Contents TRIFLEX Windows User Manual
TrueGrid ® Installation Instructions for UNIX
- Silvaco
G4250 Micro Gyro User Manual
VWF Interactive Tools
SFLM Installation Guide
Software Package on Integrated Nonlinear Dynamic Modeling and
Simulating Radiation-Induced Shifts in MOSFET Threshold Voltage
August - Silvaco
HiSIM Methodology for the Parameter Extraction in
Simucad Management Console (SMAN)