IMPACT Statement
SELB selects the impact ionization model described by Selberherr [2].
N.CONCANNON, P,CONCANNON set the Concannon substrate current model.
TOYABE is a synonym for SELB.
Note: If no model selection flag is set, the model parameters from Grant [29] are used. See Chapter 3: “Physics”, “Grant’s
Impact Ionization Model” Section on page 3-75.
Electric Field Model Selection Flags
The default electric field to use for ionization rate calculations is calculated as the modulus of the
electric field over a triangle. In ATLAS3D, this is combined with the z-component of the field at each
corner of the prism to give an overall field modulus at each node. This corresponds to Equation 3-260
in Chapter 3: “Physics” for a triangle.
E.DIR specifies that the impact ionization rate will be calculated as a function of the electric field in
the direction of the current (see Equation 3-259 in Chapter 3: “Physics”). Its alias is NEW.
E.SIDE specifies that the impact ionization rate will be calculated as a function of the electric field
along the side of the triangle (see Equation 3-258 in Chapter 3: “Physics”). This model is only
supported in ATLAS2D. Its alias is OLD.
E.VECTOR specifies that the vector electric field will be used in the calculated of the impact
ionization rate (see Equation 3-257 in Chapter 3: “Physics”).
OLD is the model that corresponds to Equation 3-261 in Chapter 3: “Physics” and is only supported in
ATLAS2D.
NEW is the model that corresponds to Equation 3-262 in Chapter 3: “Physics”, where the component
of the field in the direction of the current is used in the ionisation rate calculation. It is implemented
in both ATLAS2D and ATLAS3D. If the dot product of E and J is negative, then the field component is
taken as 0. Consequently, impact ionisation may only occur when a current is dominated by the drift
term.
Model Localization Parameters
DEVICE specifies the device in MIXEDMODE simulation to which the statement should apply.
MATERIAL specifies what material from Appendix B: “Material Systems”, Table B-1 the statement
should apply. If a material is specified then all regions defined as being composed of that material will
be affected.
NAME specifies what region that the IMPACT statement should apply. Note that the name must
match the name specified in the NAME parameter of the REGION statement.
REGION specifies that index of the region to which the impact parameters apply.
Valdinoci Model Parameters
VAL.AN0 specifies the value of a temperature dependent impact ionization parameter in Chapter 3:
“Physics”, Equation 3-270.
VAL.AN1 specifies the value of a temperature dependent impact ionization parameter in Chapter 3:
“Physics”, Equation 3-270.
VAL.AN2 specifies the value of a temperature dependent impact ionization parameter in Chapter 3:
“Physics”, Equation 3-270.
VAL.BN0 specifies the value of a temperature dependent impact ionization parameter in Chapter 3:
“Physics”, Equation 3-270.